Marantz PDxx01 User Manual
Page 13
PDxx01
RS-232C Control Specification Page: 13 / 49
Document Version [1.0]
Company Restricted
5-13.
COLOR TEMP SELECT
Function
The external control equipment changes the COLOR TEMP of the plasma monitor.
Transmission Data
DFH 80H 60H 00H 01H DATA00 CKS
DATA00: 00H:
low
01H:
middle
02H:
high
03H: middle low
ACK
7FH 60H 80H 00H 01H DATA00 CKS
DATA00: 00H:
low
01H:
middle
02H:
high
03H: middle low
5-14.
RED Gain Data
Function
The external control equipment changes the RED Gain Data of the plasma monitor.
Transmission Data
DFH 80H 60H 7FH 04H DATA00 to DATA03 CKS
DATA00: USER PICTURE Gain Flag
01H
DATA01: RED Gain Flag
01H
DATA02: RED Gain 1(Bias)
D8H : -40
:
FFH : -01
00H : 0
01H : +01
:
1EH : +30
DATA03: RED Gain 2(Drive)
D8H : -40
:
FFH : -01
00H : 0
01H : +01
:
1EH : +30
ACK
7FH 60H 80H 7FH 02H DATA00 DATA01 CKS
DATA00: USER PICTURE Gain Flag
01H
DATA01: RED Gain Flag
01H