Marantz PDxx01 User Manual
Page 21
PDxx01
RS-232C Control Specification Page: 21 / 49
Document Version [1.0]
Company Restricted
5-31.
GRAY LEVEL Set
Function
The external control equipment sets the GRAY LEVEL of the plasma monitor.
Transmission Data
DFH 80H 60H C6H 01H DATA00 CKS
DATA00: GRAY LEVEL
00H: 0
:
0FH:
15
ACK
7FH 60H 80H C6H 01H DATA00 CKS
DATA00: GRAY LEVEL
00H: 0
:
0FH:
15
5-32.
CINEMA MODE Set
Function
The external control equipment switches on or off the CINEMA MODE of the plasma monitor.
Transmission Data
DFH 80H 60H C1H 01H DATA00 CKS
DATA00: CINEMA MODE Set
01H: ON
02H: OFF
ACK
7FH 60H 80H C1H 01H DATA00 CKS
DATA00: CINEMA MODE Set
01H: ON
02H: OFF
5-33.
LONG LIFE Set (PDP SAVER Set)
Function
The external control equipment sets the PLE, ORBITER, and INVERSE (inverse of image brightness) or WHITE of the plasma
monitor.
Transmission Data
DFH 80H 60H 6BH 03H DATA00 DATA01 DATA02 CKS
DATA00: PLE
01H: 100% (AUTO)
02H: 75% (LOCK1)
03H: 50% (LOCK2)
04H: 25% (LOCK3)
DATA01: INVERSE/WHITE
01H: INVERSE
02H:
OFF
03H:
WHITE
DATA02: ORBITER (PICTURE SHIFT)
01H: AUTO1
02H:
OFF
03H:
AUTO2
ACK
The plasma monitor returns the following ACK when setting the PLE, ORBITER, and INVERSE (inverse of image brightness) or
WHITE:
3FH 60H 80H 6BH 00H CKS