NOTE REGARDING VENTED PRODUCTS

This product must be installed by a licensed plumber or gas fitter

when installed within the Commonwealth of Massachusetts.
Any residence with a direct vent product must have a CO detector

installed in the residence.
Installation of the fireplace or vented gas log in the State of

Massachusetts requires the damper to be permanently removed or

welded in the fully open position.
In addition, a naturally vented gas log may not be installed in a

bedroom or bathroom in the State of Massachusetts.
Flex line installation must not exceed 36 inches and must have a

T shutoff valve.

NOTE REGARDING VENT FREE PRODUCTS

This product must be installed by a licensed plumber or gas fitter

when installed within the Commonwealth of Massachusetts.
In addition, vent free products may not be installed in a bedroom or

bathroom regardless of size or type in the State of Massachusetts.
Flex line installation must not exceed 36 inches and must have a

T shutoff valve.

CARBON MONOXIDE DETECTOR REQUIREMENTS

(2) Revise 10.8.3 by adding the following additional

requirements:
(a) For all side wall horizontally vented gas fueled equipment

installed in every dwelling, building or structure used in whole or

in part for residential purposes, including those owned or operated

by the Commonwealth and where the side wall exhaust vent

termination is less than seven (7) feet above finished grade in the

area of the venting, including but not limited to decks and porches,

the following requirements shall be satisfied:
1. Installation of carbon monoxide detectors. At the time of

installation of the side wall horizontal vented gas fueled equipment,

the installing plumber or gas fitter shall observe that a hard wired

carbon monoxide detector with an alarm and battery back-up is

installed on the floor level where the gas equipment is to be installed.

In addition, the installing plumber or gas fitter shall observe that a

battery operated or hard wired carbon monoxide detector with an

alarm is installed on each additional level of the dwelling, building

or structure served by the side wall horizontal vented gas fueled

equipment. It shall be the responsibility of the property owner

to secure the services of qualified licensed professionals for the

installation of hard wired carbon monoxide detectors

a. In the event that the side wall horizontally vented gas

fueled equipment is installed in a crawl space or an attic, the hard

wired carbon monoxide detector with alarm and battery back-up

may be installed on the next adjacent floor level.

b. In the event that the requirements of this subdivision can

not be met at the time of completion of installation, the owner

shall have a period of thirty (30) days to comply with the above

requirements; provided, however, that during said thirty (30) day

period, a battery operated carbon monoxide detector with an alarm

shall be installed.

Massachusetts Residents Only — Please read and follow these special requirements

2. Approved Carbon Monoxide Detectors. Each carbon monoxide

detector as required in accordance with the above provisions shall

comply with NFPA 720 and be ANSI/UL 2034 listed and IAS

certified.
3. Signage. A metal or plastic identification plate shall be

permanently mounted to the exterior of the building at a minimum

height of eight (8) feet above grade directly in line with the

exhaust vent terminal for the horizontally vented gas fueled

heating appliance or equipment. The sign shall read, in print size

no less than one-half (1/2) inch in size, “GAS VENT DIRECTLY

BELOW. KEEP CLEAR OF ALL OBSTRUCTIONS.”
4. Inspection. The state or local gas inspector of the side wall

horizontally vented gas fueled equipment shall not approve the

installation unless, upon inspection, the inspector observes carbon

monoxide detectors and signage installed in accordance with the

provisions of 248 CMR 5.08(2)(a)1 through 4.
(b) Exemptions: The following equipment is exempt from 248

CMR 5.08(2)(a)1 through 4:
1. The equipment listed in Chapter 10 entitled "Equipment Not

Required To Be Vented" in the most current edition of NFPA 54 as

adopted by the Board; and
2. Product Approved side wall horizontally vented gas fueled

equipment installed in a room or structure separate from the

dwelling, building or structure used in whole or in part for

residential purposes.
(c) Manufacturer requirements — Gas Equipment Venting

System Provided. When the manufacturer of Product Approved

side wall horizontally vented gas equipment provides a venting

system design or venting system components with the equipment,

the instructions provided by the manufacturer for installation of

the equipment and the venting system shall include:
1. Detailed instructions for the installation of the venting system

design or the venting system components; and
2. A complete parts list for the venting system design or venting

system.
(d) Manufacturer requirements — Gas Equipment Venting

System Not Provided. When the manufacturer of a Product

Approved side wall horizontally vented gas fueled equipment

does not provide the parts for venting the flue gases, but identifies

“special venting systems,” the following requirements shall be

satisfied by the manufacturer:
1. The referenced "special venting system" instructions shall be

included with the appliance or equipment installation instructions;

and
2. The “special venting systems” shall be Product Approved by the

Board, and the instructions for that system shall include a parts list

and detailed installation instructions.
(e) A copy of all installation instructions for all Product Approved

side wall horizontally vented gas fueled equipment, all venting

instructions, all parts lists for venting instructions, and/or all

venting design