I. PREOPERATIONAL TESTS

ALL dryers are thoroughly tested and inspected before leaving the factory. However, a preoperational test

should be performed before the dryer is publicly used. It is possible that adjustments have changed in transit or

due to marginal location (installation) conditions.

1. Turn on electric power to the dryer.

2. Refer to the Operating Instructions for starting your particular model dryer.

3. GAS MODELS ONLY

a. When a gas dryer is first started (during initial start-up), it has a tendency not to ignite on the first ignition

attempt. This is because the gas supply piping is filled with air, so it may take a few minutes for the air to

be purged from the lines.

NOTE: During the purging period, check to be sure that ALL gas shut-off valves are open.

NOTE: Gas model dryers are equipped with a Direct Spark Ignition (DSI) system which has internal

diagnostics. If ignition is not established after the first attempt, the heat circuit in the DSI module

will lock out until it is manually reset. To reset the DSI (Direct Spark Ignition) system, open
and close the main door and restart the dryer.

b. A gas pressure test should be taken at the gas valve pressure tap of each dryer to assure that the water

column (W.C.) pressure is correct and consistent.

NOTE: Water column (W.C.) pressure requirements (measured at the pressure tap of the gas valve

body):

Natural Gas ----------------- 3.5 Inches Water Column (W.C.)

Liquid Propane (L.P.) Gas ---10.5 Inches Water Column (W.C.)

IMPORTANT: There is no regulator provided in an L.P. dryer. The water column pressure must be

regulated at the source (L.P. tank), or an external regulator must be added to each

dryer.

4. Make a complete operational check of ALL safety related circuits:

a. Door Switches

b. Hi-Limit thermostats

c. Cycling thermostat

d. GAS Models - Sail Switch

NOTE: The sail switch can be checked for proper operation by opening the lint door while heating

circuit (gas burner/electric oven) is active (on). The heating unit should shut off within a few

seconds. If not, make necessary adjustments to the sail switch.