beautypg.com

Maintenance, Warning – Graco HIGH-FLO 220-569 User Manual

Page 15

background image

307-809

15

Maintenance

The operating conditions of your particular system

determine how often maintenance is required. Estab-

lish a good maintenance schedule during the first

several weeks of operation by recording when and

what kind of maintenance is needed, and then deter-

mine a regular schedule for checking your system.

Your maintenance schedule should include the follow-

ing:

Flushing

WARNING

FIRE AND EXPLOSION HAZARD

Before flushing, read the section

FIRE

AND EXPLOSION HAZARD on page

5. Be sure the entire system and flush-

ing pails are properly grounded. Refer to

Grounding on page 7.

1. Flush before shutting down the system for an

extended period of time.

2. Flush before repairing the pump, if possible.

3. Flush before the fluid you are pumping can dry out,

settle or set up in the pump and hoses.

Packing Nut Tightness

The packing nut (21) should be tight enough to stop

leakage, but no tighter. Overtightening compresses

and damages the packings, and may cause the pump

to leak, reducing performance. See Fig. 4.

To check the adjustment of the packing nut, first re-

lieve fluid pressure. If you have a torque wrench,

tighten the packing nut to 34–40 NSm (25–30 ft–lb).

Excessive Leaking at Throat

To monitor leaking at the throat, remove one of the

small plugs (31) from the packing nut (21). Place one

end of a drain tube in the hole and the other end in a

container. See Fig. 4. Monitor the drainage. If it seems

excessive, and tightening the packing nut does not

help, replace the throat packings. See page 20.

Fig. 4

01925

21

31

31

1

Torque to 34–40 NSm

(25–30 ft–lb).

1