10

307-809

Installation (Hydraulic-Powered Pumps)

Hydraulic Power Supply

CAUTION

The Hydraulic Power Supply must be kept clean at

all times to avoid damage to the motor and hydraulic

power supply.

1. Blow out hydraulic lines with air and flush thor-

oughly before connection to the motor.

2. Plug hydraulic inlets, outlets, and line ends when

disconnecting them for any reason.

1. Be sure the power supply can provide sufficient

power to the motor.

2. Be sure the power supply is equipped with a

suction filter to the hydraulic pump.

Hydraulic Supply to Motor

NOTE: The motor’s hydraulic inlet is 3/4 in., 37_ flare.

Use a minimum 13 mm (1/2 in.) ID hydraulic supply

line (L).

1. The shutoff valve (R) isolates the motor when

servicing the system. See Fig. 3.

2. The hydraulic fluid pressure gauge (Q) monitors

the hydraulic oil pressure to the motor. This helps

avoid overpressurizing the motor or displacement

pump.

3. The pressure- and temperature-compensated flow

control valve (S) prevents the motor from running

too fast, which can damage it.

4. The pressure reducing valve (P) which has a drain

line (M) running to the return line (K), controls the

hydraulic pressure to the motor.

Hydraulic Return from Motor

NOTE: The motor’s hydraulic outlet is 7/8 in., 37_

flare. Use a minimum 16 mm (5/8 in.) ID hydraulic

return line (K).

1. The shutoff valve (R) isolates the motor when

servicing the system.

CAUTION

To avoid damage to the pump, never use the return

line shutoff valve to control the hydraulic flow. Do not

install any flow control devices on the hydraulic re-

turn line.

2. The 10 micron size return filter (J) removes resi-

due from the hydraulic fluid to help keep the sys-

tem running smoothly.

Fluid Line from Pump

WARNING

A fluid drain valve (J) is required in your system, to

help reduce the risk of serious injury including

splashing in the eyes or on the skin if the pump

cycles unexpectedly.

Locate one valve downstream from the pump outlet

and another valve downstream from the surge tank

(G). These drain valves are used to relieve fluid

pressure in the pump and surge tank during shut-

down.

1. The surge tank (G) reduces fluid surging to pre-

vent backflow into the pump. Mounting instructions

are supplied with the tank.

2. The shutoff valves (D) before and after the surge

tank, and between each mix tank and the pump

fluid inlet, isolate these components for servicing.

3. Be sure the supply line (C) between the pump and

mix tanks is level.