beautypg.com

Flat spray tips – Graco FUSION 309550U User Manual

Page 18

background image

Flat Spray Tips

18

309550U

Flat Spray Tips

1.

Follow Pressure Relief Procedure, page 15.

2.

Remove air cap (10) and flat spray tip (39). Inspect

o-ring (40).

If tip is stuck, pry off with small screwdriver or pull
off with pliers. Tip is hardened to resist damage.

3.

To clean, soak tip in compatible solvent, see page

20. Clean gently with tip cleanout tool 15D234,
page 44, to fit tip configuration.

TI2557A

10

39

40

4.

Reposition tip horizontally or vertically, or install dif-

ferent tip size.

Tips marked on back with last 3 digits of part no.
See Flat Tip Part No. Reference Guide, page
38.

5.

Reinstall air cap hand tight. Cleaning hole align-

ment to tip not important.

TI2649A

TI2648A