beautypg.com

Nd 17, Optional hose position – Graco FUSION 309550U User Manual

Page 17

background image

Optional Configurations

309550U

17

Optional Hose Position

Fluid inlet swivels and air quick disconnect fitting point to
rear. If desired, these positions can be changed so
hoses travel downward.

CAUTION

To prevent cross-contamination of gun’s wetted parts,
do not interchange A component (isocyanate) and B
component (resin) parts.

1.

Follow Pressure Relief Procedure, page 15. Also

relieve system pressure, see proportioner manual.

2.

Disconnect air (D) and remove fluid manifold (M).

3.

Disconnect fluid hoses from inlet swivels (A, B).

Remove swivels. Remove plugs from optional
inlets (P).

TI2554A

M

D

TI2417A

P

A

B

4.

Apply thread sealant to plugs (12c), elbows (50*),

and male threads of swivels (A, B). Install elbows
(50*) in optional inlets (P), facing down. Install
swivels (A, B) in elbows. Be sure to install A swivel
(smaller) in A side. Install plugs where swivels had
been. Torque all parts to 235-245 in-lb (26.6-27.7
N•m).

5.

Connect A and B hoses to A and B swivels.

6.

Remove fitting (D) and plug (J). Reverse positions.

Apply thread sealant and torque to 125-135 in-lb
(14-15 N•m).

7.

Attach fluid manifold. Connect air. Return gun to

service.

TI2646A

50*

B

P

A

12c

Elbows (50*) are not included with spatter spray
gun.

TI2540A

J

D