beautypg.com

Technical specification – Stovax VFC Radiant & Convector Fire Range User Manual

Page 8

background image

8

TECHNICAL SPECIFICATION

THESE INSTRUCTIONS COVER THE FOLLOWING MODELS:

VFC RADIANT

VFC COVECTOR

VFC LOW CONVECTOR

8300UC 16”

8420UC 16”

8461UC 16”LL

P8300UC 16”

P8420UC 16”

P8461UC 16”LL

8301UC 16”RD

8421UC 16”RD

8463UC 16”RD LL

P8301UC 16”RD

P8421UC 16”RD

P8463UC 16”RD LL

8305UC 18”

8425UC 18”

8466UC 18”LL

P8305UC 18”

P8425UC 18”

P8466UC 18”LL

8310UC 22”

8430UC 22”

8471UC 22”LL

P8310UC 22”

P8430UC 22”

P8471UC 22”LL

Model

Gas

Gas

Working Aeration Injector Gas Rate

Input kW (Gross)

Country

CAT.

Type

Pressure

m

3

/h

High

Max Flue

Temp.

I2H Natural(G20) 20mbar

12N

400

•653

GB,IE

Butane(G30)

29mbar

•190

Propane(G31) 37mbar

•250

6.85

RDL

I3+

180

6.65

GB,IE

160°C

I2H Natural(G20) 20mbar

12N

600

•900

GB,IE

Butane(G30)

29mbar

•272

Propane(G31) 37mbar

•358

9.45

9L

I3+

260

9.50

GB,IE

190°C

I2H Natural(G20) 20mbar

11N

700

1•010

GB,IE

Butane(G30)

29mbar

•303

Propane(G31) 37mbar

•399

10.60

9L

I3+

300

10.60

GB,IE

200°C

I2H Natural(G20) 20mbar

9N

850

1•172

GB,IE

Butane(G30)

29mbar

•363

Propane(G31) 37mbar

•478

12.30

0L

I3+

360

12.70

GB,IE

210°C

16 RD

16

18

22

MINIMUM FLUE SIZE

178mm (7”)

INLET CONNECTION SIZE

8mm

MIN FLUE SPECIFICATION

T260/N2/0/D/1