20

5. ODS PILOT UNIT

Note: The pilot unit on the appliance is a non serviceable unit due

to the complex nature of its manufacture. Replacement of the

complete unit must be carried out when one of the following

items becomes faulty:

Pilot injector

Ignition electrode

Thermocouple

5.1 Carry out operations (a) to (d), section 4.

5.2 Gently pull the ignition lead off the electrode. See diagram 5

arrow A.

5.3 Remove the two screws securing the pilot assembly. See

diagram 5 arrow B.

5.4 Undo the thermocouple connection at the back of the gas

valve. See diagram 6 arrow A.

5.5 Replace with a new pilot assembly, set the spark gap. See

diagram 7.

5.6 After reassembly, check for gas soundness and carry out a

flame failure functional check details in the flow chart,

especially the mag drop out time.

6. GAS VALVE

6.1 Turn the gas supply off at the isolation device.

6.2 Disconnect the 2x8mm and 1x4mm gas pipe fittings at the

back of the gas valve and also disconnect the thermocouple,

see diagram 8 arrow B.

6.3 Undo the single screw that secures the left hand side of the

control cover, see diagram 9.

6.4 To release the right hand side of the control cover insert the

narrow blade screwdriver into the slot shown in diagram 10,

lever it gently and pull from the right hand side at the same

time. The cover will now come off, there is a small cylindrical

metal spacer inside the cover, this must be kept and replaced

on the fixing screw during re-assembly.