beautypg.com

Installation instructions, Installation – Stovax VFC Radiant & Convector Fire Range User Manual

Page 12

background image

12

4.8 Fit the fret to the fire front using two screws. See diagram 4.

5. INSTALLATION - CONVECTOR FIRES

5.1 Make any necessary alterations to fireplace opening. Ensure

that the lintel does not obstruct the flue outlet into the flue,

and that there is a clear space for debris of at least 90mm. See

diagram 5.

5.2 Gas pipe entry must be through one of the holes in the rear

of the convector box. See diagram 6 & 7.

Note: Gas pipes passing through masonry must be protected.

5.3 If the isolation tap is to be fitted under the fire, the GAZCO

GC0060 provides a neat and easy solution. See diagram 7A.

5.4 Remove the fire assembly (see diagram 9), and offer the

convector box into the opening, checking that it fits squarely.

Mark the fixing holes and the gas pipe entry positions. See

diagram 8.

5.5 Fit the gas pipe into position, ready for passing into the

convector box, ensuring enough remains to connect to the

fire.

5.6 Carefully fit the convector box, feeding the piping through into

the box. Secure the box to the wall, through the flange or base

ensuring that the box is square in the opening. Any

undulations or gaps between the convector box and the wall

should be filled with a non-combustible material. Do not use

silicone as it makes future removal almost impossible.

5.7 Refit the fire assembly and front air guide back into the

convector box. See diagram 9.

5.8 HAVE YOU PURGED THE GAS SUPPLY PIPES.

This is essential to expel any foreign matter that might get

blown into the valve assembly causing blockages.

INSTALLATION INSTRUCTIONS

INSTALLATION

4

5

6

7

7A

8

AR0311

AR0300

AR0200

AR0313

AR0314

9