beautypg.com

Battery and charger instructions observe and obey, Dry battery filling and charging instructions – Genie IWP Super Series 48643 User Manual

Page 22

background image

20

Genie IWP Super Series

Part No. 48643

Operator’s Manual

Second Edition • Fourth Printing

OPERATING INSTRUCTIONS

Battery and Charger Instructions

Observe and Obey:

Do not use an external charger or booster

battery.

Charge the battery in a well-ventilated area.

Use proper AC input voltage for charging as

indicated on the charger.

Use only Genie authorized battery and charger.

To Charge Battery

1 Open the battery pack lid to access the battery.

2 Remove the battery vent caps and check the

battery acid level. If necessary, add only
enough distilled water to cover the plates. Do
not overfill prior to the charge cycle.

3 Replace the battery vent caps.

4 Set the power switch to the

OFF

position. Be

sure that the DC output cord is properly
connected to the battery.
Black to negative, red to positive.

5 Connect the battery charger to a grounded AC

circuit.

6 If equipped: Set the AC Selector switch to the

proper voltage.

7 Set the power switch to the

AUTO

position.

8 Monitor the ampere meter for the correct

charge rate. The initial charge rate should be
approximately 10A. The charge rate will
decrease as the battery reaches full charge.

9 The charger will turn off automatically when the

battery is fully charged. Set the power switch to
the

OFF

position, then disconnect from the AC

supply.

10 Check the battery acid level when the charge

cycle is complete. Replenish with distilled water
to the bottom of the fill tube. Do not overfill.

Dry Battery Filling and
Charging Instructions

1 Remove battery vent caps and permanently

remove plastic seal from battery vent openings.

2 Fill each cell with battery acid (electrolyte) until

the level is sufficient to cover the plates.

Do not fill to maximum level until battery charge
cycle is complete. Overfilling can cause the
battery acid to overflow during charging.
Neutralize battery acid spills with baking soda and
water.

3 Install the battery vent caps.

4 Charge the battery.

5 Check the battery acid level when the charging

cycle is complete. Replenish with distilled water
to the bottom of the fill tube. Do not overfill.