3.3.8

Power Budget Calculations for Magnum 1000 Series RPM’s with Fiber

Media

Receiver Sensitivity and Transmitter Power are the parameters necessary to

compute the power budget. To calculate the power budget of different fiber media
installations using Magnum products, the following equations should be used:
OPB (Optical Power Budget) = P

T

(min) - P

R

(min)

where P

T

= Transmitter Output Power, and P

R

= Receiver Sensitivity

Worst case OPB = OPB - 1dB(for LED aging) - 1dB(for insertion loss)
Worst case distance = {Worst case OPB, in dB} / [Cable Loss, in dB/Km]

where the “Cable Loss” for 62.5/125 and 50/125

µm

(M.m) is 2.8 dB/km,

and the “Cable Loss” for 100/140 (Multi-mode) is 3.3 dB/km,
and the “Cable Loss” for 9/125 (Single-mode) is 0.5 dB/km

The following data has been collected from component manufacturer’s (HP’s and
Siemens’) web sites and catalogs to provide guidance to network designers and
installers.

Fiber

Port

Module

Speed,

Std.

Mode

Std.
km

fdx

(hdx)

Wave

-

length

nm

Cable

Size

µm

X’mitr

Output

P

T ,

dB

R’cvr

Sens.

P

R ,

dB

Worst

OPB,

dB

Worst*

distance
Km, fdx

typical

OPB,

dB

typical*

distance

Km, fdx

RPM-MST,

MSC

10 Mb

FL

Multi-

mode

2

(2)

850

62.5/125

100/140

50/125

-15.0

-9.5

-19.5

-31
-31
-31

14

19.5

9.5

5

5.9
3.4

17

23.5
13.5

6
7

4.8

RPM-

SMF (ST)

10 Mb

FL

Single-

mode

10

(5)

1300

9/125

-30

-39

7

14

13

26

* Note: The use of either multi-mode or single-mode fiber to operate at 100Mbps speed

over long distances (i.e., in excess of approx. 400 meters) can be achieved

only

if the following factors are both applied:

The 100Mb fiber segment must operate in full-duplex (FDX) mode, i.e. the
full-duplex (factory default) setting for 100Mbps fiber ports must be used,
and

The worst-case OPB of the fiber link must be greater than the fiber cable’s
passive Attenuation.

(Attenuation = Cable loss + LED aging loss + Insertion loss + safety factor)

3.3.9 Rack-mounting

Installation of a Magnum

1000 Series Hub in a 19” rack is a

simple procedure. The units are 1U

(1.75”) high. When properly installed, the front-mounted LED status indicators should