background image

GXV3601 IP Camera

Firmware 1.0.4.6 Page 28 of 36
Grandstream Networks, Inc. 09/2010

than 15V, this will damage the IP camera.
Internally, the Alarm-out uses relays as a switch (30VAC/2A); users can connect devices such
as alarm siren or alert light to this port. Under normal circumstances, the circuit is open.
When there is an alarm event, the GXV3601 will close the circuit to trigger the alarm.

Connect Alarm Input Equipment to the GXV3601

Here are two sample connection diagrams. Connect the alarm equipment to the GXV3601 by
following the diagram below.



Set up Alarm Actions

An alarm action is what the GXV3601 is going to do when an alarm is triggered during the
defined time period – the time schedule. The GXV3601 allows multiple alarm actions.

Record Video

– If this option is

selected, the GXV3601 will record the
video when an alarm is triggered. You
can enter the length of the video
recording (in seconds). You can also
choose the storage method for video