TROUBLESHOOTING THIS APPLIANCE. STATUS LIGHT CODES ARE AS FOLLOWS:

THE STATUS LIGHT ON THE FURNACE CONTROL MAY BE USED AS A GUIDE TO

CC

STICKING GAS VALVE

STATUS LIGHT

EQUIP. STATUS

FALSE FLAME SENSED

OPEN LIMIT SWITCH

6 BLINKS

5 BLINKS

3 BLINKS

2 BLINKS

4 BLINKS

NORMAL OPERATION

1 BLINK

OFF

ON

VSTB

TB

INSTALLER/SERVICEMAN

TO THC

R

R

G

G

W/W2

W

Y/Y2

Y1

C

G

R

W

ECON

9

7

10

8

12

11

C

Y1

CHECK

-

B4312004 Rev. A

THC-FIELD WIRING

4. CRANKCASE HEATER (OPTIONAL).

2

3

1

5

6

4

208-230/1/60

GV

VSM

1

5

IIC

6

3

FS

FUSE

4

RS

ALS

LS

FS

IGN

L1

L1

D1

L1

L1

H

C

TRANS

VM

CC

L1

T1

C

COMP

R

S

L1

CAP1

H

C

F

T2

CC

CM

SUPPLY VOLTAGE

208-230/1/60

CH

FIELD INSTALLED POWER

VSTB VARIABLE SPEED TERM. BLOCK

IIC INTEGRATED IGNITION CONTROL

THC THERMOSTAT HEAT & COOL

2

NOTES

TB TERMINAL BLOCK

VSM VAR. SPEED MOTOR

TRANS TRANSFORMER

RS ROLLOUT SWITCH

VM VENT MOTOR

PS PRESSURE SWITCH

IGN IGNITOR

GV GAS VALVE

LS LIMIT SWITCH

PL PLUG

L2

L2

L2

R RED

Y YELLOW

W WHITE

FIELD INSTALLED CONTROL

BL BLUE

PK PINK

PU PURPLE

G GREEN

O ORANGE

BR BROWN

WIRE CODE

B BLACK

ALS AUXILLARY LIMIT SWITCH

COMP COMPRESSOR

CM CONDENSER MOTOR

CC CONTACTOR
CH CRANKCASE HEATER

FS FLAME SENSOR

COMPONENT LEGEND

CAP CAPACITOR

L2

L2

MARKED TERMINAL

LINE VOLTAGE

LOW VOLTAGE

UNMARKED TERMINAL

WIRING

WIRE SPLICE

Y

Y

C

Y2

Y2

1. REPLACEMENT WIRE MUST BE THE SAME SIZE AND TYPE OF
INSULATION AS ORIGINAL.(USE COPPER CONDUCTOR ONLY).

2. FOR 208 VOLT TRANSFORMER OPERATION MOVE BLACK WIRE
FROM TERMINAL 3 TO TERMINAL 2 ON TRANSFORMER.

3. SOME MODELS HAVE VENT MOTORS EQUIPPED WITH A 230V LEAD (RED)
AND A 208V (BLACK). IF EQUIPPED, CONNECT VENT MOTOR BLACK LEAD IN
PLACE OF RED LEAD AT UII (DI) FOR 208V OPERATION.

5. ACCESSORY ECONOMIZER PLUG (ON SELECT MODELS) ADJACENT
TO BLOWER HOUSING IN RETURN AIR COMPARMENT.

6. TWO STAGE THERMOSTAT CONNECTIONS IF USED WITH ECONOMIZER
OPTION INSTALLED.

NO POWER OR

INTERNAL CONTROL

FAULT

IGNITION FAILURE

OR

OPEN ROLLOUT

SWITCH

OR

OPEN AUX. LIMIT

SWITCH

PRESSURE SWITCH

OPEN

PRESSURE SWITCH CLOSED

WITHOUT INDUCER ON

COMPRESSOR

OUTPUT DELAY

CHECK INPUT POWER

CHECK FUSE ON CONTROL

REPLACE CONTROL

GAS FLOW

GAS PRESSURE

GAS VALVE

FLAME SENSOR

FLAME ROLLOUT

BAD SWITCH

AUX. LIMIT OPEN

CHECK

PRESSURE SWITCH

CHECK

PRESSURE SWITCH

MAIN LIMIT OPEN

BAD SWITCH

3 MIN. COMP.

ANTI-CYCLE TIMER

GPG13(48)1A WIRING DIAGRAM

HIGH VOLTAGE!
DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS
UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO
DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.

Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.