Product dimensions and clearances, The installation space, Planning information – GE Monogram ZFSB26D SS User Manual
Page 3
Planning Information
PRODUCT DIMENSIONS
AND CLEARANCES
This Monogram free-standing refrigerator requires
the following clearances for proper air circulation,
plumbing and electrical connections.
Air Circulation Clearances:
• 1/8" on each side
• 1" at the top
• 1" at the back (1-1/2" for ZFSB25)
Installation in a corner:
• Allow 4" clearance on each side to an adjacent wall
for a 90° opening and access to drawers.
THE INSTALLATION SPACE
The opening width must be 36-1/4".
3
• On the freezer side, allow 14-1/4" min. clearance
for removal of ice bin.
• On the fresh food side, allow 19" min. clearance
to wall for removal of drawers.
Water And Electrical Locations
The opening must be prepared with the electrical
and water supply located as shown.
Additional Specifications
• A 115 volt 60Hz., 15 or 20 amp power supply is
required. An individual properly grounded branch
circuit or circuit breaker is recommended. Install
a properly grounded 3-prong electrical receptacle
recessed into the back wall.
NOTE:
GFI (ground fault interrupter) is not
recommended.
• Water line can enter the opening through the
floor or through an adjacent cabinet, as close to
the back wall as possible. The water line should be
1/4" O.D. copper tubing between the cold water
line and water connection location at the rear of the
refrigerator. Installation of an easily accessible shut
off valve in the water line is recommended.
19"
14-1/4"
160
° Door Swing
36"
72"
34"
Including
Handles
32"
Depth
Wall View
Electrical
Area
73" min.
Water Supply
36-1/2"
72-1/4"
36"
30-1/2"
Including
Handles
28"
Depth
ZFSB26
ZFSB25
ZFSB25 and ZFSB26
ZFSB25 ZFSB26