EXHAUSTING THE DRYER (cont.)

WARNING –

NEVER LEAVE

THE BACK OPENING WITHOUT THE PLATE.

(Kit WE1M454)

Installation Instructions

SIDE VENTING (cont.)

Connect standard metal elbows and ducts to

complete the exhaust system. Cover back opening

with a plate (Kit WE1M454) available from your

local service provider. Place dryer in final location.

ADDING COVER PLATE TO REAR OF CABINET
(SIDE EXHAUST)

ADDING ELBOW AND DUCT FOR EXHAUST

TO LEFT OR RIGHT SIDE OF CABINET (cont.)

Plate
(Kit WE1M454)

Apply duct tape as

shown on the joint

between the dryer

internal duct and

the elbow, and also

the joint between the

elbow and the side duct.

CAUTION:

Use

4" rigid metal ducting only inside the dryer.

Internal duct joints must be secured with tape,

otherwise they may separate and cause a safety

hazard

.

Duct tape

WARNING –

BEFORE PERFORMING

THIS EXHAUST INSTALLATION, BE SURE TO

DISCONNECT THE DRYER FROM ITS ELECTRICAL

SUPPLY. PROTECT YOUR HANDS AND ARMS

FROM SHARP EDGES WHEN WORKING INSIDE

THE CABINET. BE SURE TO WEAR GLOVES.

BOTTOM VENTING:

Dryer Exhaust to the bottom of cabinet

for Gas and Electric models.

Remove the screw inside the dryer exhaust duct

and save. Pull the duct out of the dryer. Detach

and remove the bottom knockout.

Remove
screw
and save

Remove desired
knockout (one only)

Fixing hole

Cut the duct as shown and keep portion A.

A