Installation Instructions

TEST FOR LEAKS

WARNING –

Never use an

open flame to test for gas leaks.

Check all connections for leaks with soapy solution

or equivalent.
Apply a soap solution. The leak test solution must

not contain ammonia, which could cause damage

to the brass fittings.
If leaks are found, close the valve, retighten the

joint and repeat the soap test.

Open Gas
Valve

ELECTRICAL CONNECTION

INFORMATION FOR GAS DRYERS

WARNING –

To reduce the risk of

fire, electrical shock and personal injury:
Do not use an extension cord or an adapter plug

with this appliance.

The dryer must be electrically grounded in

accordance with local codes and ordinances,

or in the absence of local codes, in accordance

with the NATIONAL ELECTRICAL CODE, ANSI/NFPA

NO. 70.

ELECTRICAL REQUIREMENTS

FOR GAS DRYERS

This appliance must be supplied with 120V, 60Hz,

and connected to a properly grounded branch

circuit, protected by a 15- or 20-amp circuit

breaker or time-delay fuse.
If electrical supply provided does not meet

the above specifications, it is recommended that

a licensed electrician install an approved outlet.

WARNING –

This dryer is equipped

with a three-prong (grounding) plug for your

protection against shock hazard and should be

plugged directly into a properly grounded three-

prong receptacle. Do not cut or remove the

grounding terminal from this plug.

Ensure proper
ground exists
before use.

If local codes permit, an external ground wire (not

provided), which meets local codes, may be added

by attaching to the green ground screw on the rear

of the dryer, and to an alternate established ground.

Ensure proper ground exists before use.

Ground
Screw