Gemini GEM-RP8 User Manual
Page 13

13
Keypad Beeps or
H
Flashes
Zone light
ON
System Trouble
Condition
Action
2 Beeps
2
Fire Trouble
A problem has been detected in the Fire Circuit.
Call installing company for service.
2 Beeps
3
Wireless Receiver
Trouble
A problem has been detected with the wireless receiver.
Call installing company for service.
2 Beeps
4
Wireless Receiver Jam A problem has been detected with a wireless receiver.
Call installing company for service.
3 Beeps
1-8
Wireless Transmitter
Low Battery
The battery in a wireless transmitter is low and should be replaced. This transmitter is
on the zone corresponding to the number of the lit zone light. The replacement battery
for the GEM-Trans2 door/window transmitter, GEM-PIR motion detector and GEM-GB
glass break detector is the Duracell DL123A 3 volt lithium. (2 required for the GEM-PIR
and GEM-GB). The GEM-DT Dual Technology Sensor requires 4 C cell alkaline
batteries. Warning: Replace batteries only with the same type as specified above. Use
of another battery may present a risk of fire or explosion. Do not recharge or
disassemble battery, or dispose of in fire.
4 Beeps
1-8
Wireless Transmitter
Supervisory Failure
A problem has been detected with a wireless transmitter.
Call installing company for service
5 Beeps
1-4
Wireless Smoke
Detector Low Battery
The battery in a wireless smoke detector is low and should be replaced. This wireless
smoke detector should be marked with a number corresponding to the number of the lit
zone light. The replacement battery is the Duracell MN1604 9 Volt Alkaline(2 required).
Warning: Replace batteries only with the same type as specified above. Use of another
battery may present a risk of fire or explosion. Do not recharge or disassemble battery,
or dispose of in fire.
6 Beeps
1-4
Wireless Smoke
Detector Supervisory
Failure
A problem has been detected with a wireless smoke detector.
Call installing company for service.
7 Beeps
1-6
Zone Trouble
Call installing company for service.
H
S Y S T E M T R O U B L E S