Diagnostic log – Geneva Lab FRESH BREW 3206 User Manual

Page 28

background image

26

G E N E V A

-

H O T B E V E R A G E M E R C H A N D I S E R • 3 2 0 5 • 3 2 0 6 • 4 2 1 4 8 0 3

DIAGNOSTIC LOG

Displayed Message

Explanation of Condition

KEY STUCK

A key on the user keypad has been closed continuously for >15
seconds

WATER LEAKAGE

The hot inlet valve has had to be switched on > 30 times since
the last vend was taken

NO CUPS

Comes into force after 2 unsuccessful attempts to drop a cup

ELECTRONICA

Internal serial communication failure between the control board
and the RIO board

IO CONFIG ERR.

Board has not been initialized using the ENG LINK

WASTE TRAY FULL

Either the Liquid or Coffee ground waste bucket is full of water

HEATER INHIBITED

The heater tank has not filled within the 3.5 minute time limit

PLACE OWN CUP

Sold-out of cups

FILLING BOILER

Comes into force 15 seconds after starting to fill the heater tank
with water. Indication of a slow rate of fill

C BREWER FAULT

Brewer unit is not cycling correctly – a motor or cycle-switch fault

NEW FILTER REQD

Filter belt warning (if activated) – comes into force after air
pressure seen to be present after 7 seconds

FILTER BROKEN

Brewer Fault – comes into force after air pressure has seen to be
present after 20 seconds during a vend

DOOR FAULT

Cup door mechanism is not cycling correctly - a motor or cycle-
switch fault


NOTES:

1)

The event log will only record events that persist for two or more consecutive event log checks. Event
log checks take place once every 60s, so in the worst case scenario an event may have to be in force
for almost 120s before it is recorded.

2)

The event log does not handle concurrent events. If two (or more) fault conditions are active, only the
first occurrence will be recorded.