beautypg.com

Grizzly G1028Z/G1029Z User Manual

Page 13

background image

G1028Z/G1029Z Dust Collector

-11-

G1029Z

220V Operation

Extension Cords

Using extension cords may reduce the life of the
motor. Instead, place the machine near a power
source. If you must use an extension cord:

Use at least a 14 gauge cord that does not
exceed 50 feet in length!

The extension cord must also have a ground
wire and plug pin.

A qualified electrician MUST size cords over
50 feet long to prevent motor damage.

Figure 2. 6-15 plug and receptacle.

Full Load Amperage Draw

This machine draws the following amps under
maximum load:

Amp Draw .............................................. 12 Amps

Power Supply Circuit Requirements

You MUST connect your machine to a grounded
circuit that is rated for the amperage given below.
Never replace a circuit breaker on an existing cir-
cuit with one of higher amperage without consult-
ing a qualified electrician to ensure compliance
with wiring codes.

If you are unsure about the

wiring codes in your area or you plan to con-

nect your machine to a shared circuit, consult

a qualified electrician.

Minimum Circuit Size ............................. 15 Amps

Serious personal injury could occur if you

connect the machine to power before com-

pleting the setup process. DO NOT connect

the machine to the power until instructed

later in this manual.

Electrocution or fire could

result if machine is not

grounded and installed in

compliance with electrical

codes. Compliance MUST

be verified by a qualified

electrician!

Power Connection Device

The type of plug required to connect your machine
to power depends on the type of service you cur-
rently have or plan to install. We recommend
using the plug shown in

Figure 2.