4
824–001
Installation
Typical Installation – Pressure Washer
Fig. 1
HIGH PRESSURE
HOSE CONNECTION
HOSE
RACK
INLET WATER
CONNECTION
3/4” GARDEN
HOSE
SPRAY
GUN
SPRAY
HOSE
7329B
Check for Shipping Damage
Check the unit for any damage that may have occurred in
shipping. Notify the carrier immediately if there is any
damage.
Set Up
Connect the high pressure hose between the pump outlet
and the gun inlet. Both of these connections are made
with quick couplers.
CAUTION
Up to 100 ft (30 m) of high pressure hose may
be used. Longer hoses may affect sprayer
performance, and chemical injector performance,
if used.
Install the appropriate spray tip on the wand. See Install-
ing and Changing Spray Tips. If you are using a
sandblaster kit, see its separate manual for installation
instructions.
Connect to Water Supply
CAUTION
Before attaching to the water supply, check your
local plumbing code regarding cross–connection
to the water supply. If required, a backflow
preventer may be installed.
If inlet water pressure is over 60 psi (4.1 bar), a
regulating water valve must be installed at the
garden hose connection.
Do not exceed 160
_
F (70
_
C) inlet water
temperature.
Connect a hose with at least a 3/4 inch (19 mm) ID from
the water supply to the unit’s 3/4 inch garden hose inlet.
The supply hose should not be more than 50 ft (15 m)
long
NOTE: The water source at the unit
must have a mini-
mum flow rate equal to that of the unit (see Tech-
nical Data, inside back cover).