824–001

Problem

Cause

Solution

Frequent or prema-
ture failure of the
packings

Scored, damaged or worn plungers.

Install new plungers. See PUMP SERVICE, page 13.

Abrasive material in the fluid being
pumped.

Install proper filtration on pump inlet plumbing.

Inlet water temperature too high.

Check water temperature; may not exceed
160

_

F(70

_

C).

Overpressurizing pump.

Do not modify any factory–set adjustments. See
EQUIPMENT MISUSE HAZARD on page 3.

Excessive pressure due to partially
plugged or damaged tip.

Clean or replace tip. See Installing and Changing
Spray Tips on page 7.

Pump running too long without spraying.

Never run pump more than 10 minutes without spray-
ing.

Running pump dry.

Do not run pump without water.

Strong surging at in-
let and low pressure
on discharge side

Foreign particles in the inlet or discharge
valve or worn inlet and/or discharge
valves.

Clean or replace valves. See PUMP SERVICE, page
13.