beautypg.com

Troubleshooting – Global Machinery Company 50L User Manual

Page 12

background image

12

Troubleshooting

Problem

Possible Cause

Suggested Remedy

Motor will not

run, running

too slow or

becoming

excessively hot

Power fault or supply voltage too low

Check the power supply. Do not use an extension cord with
an air compressor. Make sure that the compressor is plugged
directly into a 240V household power point and not an
extension cord or power board.

Faulty pressure switch

Use authorised service centre to repair or replace the switch

Faulty motor

Use authorised service centre to repair or replace the motor

Main compressor sticking/tight

Use authorised service centre to repair or replace faulty parts

Main compressor

sticking/tight

Moving parts damaged by heat
due to insufficient lubrication

Use authorised service centre to check crankshaft, bearings,
con rod, piston rings, etc and replace where necessary

Moving parts damaged or blocked
by foreign particle

Vibration or

abnormal noise

Loose part

Use authorised service centre to check and repair if necessary

Foreign body in main compressor

Use authorised service centre to check and clean if necessary

Piston connecting with the valve seat

Use authorised service centre to increase size of gasket

Moving parts excessively worn

Use authorised service centre to repair or replace

WARNINGS.

1. Never attempt to remove any part of the compressor

whilst the tank is under pressure.

2. Never attempt to remove any electrical component whilst

the compressor is connected to the power supply. Switch

off the power and remove the electrical plug.

3. Do not adjust the safety valve.
4. Do not use an electrical extension cable.
5. If the release valve under the pressure switch cover (2)

fails to operate when the On/Off lever (3) is set in the off

position, switch the power supply off and determine the

nature of the fault.

6. Ensure that the lubricating oil is clean and that the oil level

is maintained at the mid point of the red circle in the oil

level glass (16).

7. Take care when discharging air from the tank, i.e. from the

safety valve (8), the drain cock (10) or the air outlet (6).

Compressed air can be extremely dangerous.

Take care; make sure that the discharge air does not

cause dust, stones or any other foreign particles to be

blown through the air and that the air is discharged in

a safe manner.