beautypg.com

Ge digital energy, Ml series – GE 500 User Manual

Page 4

background image

OPM_MLE_LTE_350_1K0_1GB_V011

3

DE ML Series: user manual 1.1 (GB)

GE Digital Energy

ML Series

g

2.2 Installation

Procedure

1.

Switch off your computer, and unplug it from the

socket-outlet.

2.

Disconnect the power cord from the computer (rating

250Vac/10A) and connect this cord to the male input

socket (2) at the rear of the UPS (figures on the right

show simplified ML 350-700 model).

3.

Using the output cord provided, connect the computer

to the appliance outlets (3) of the unit.

4.

Connect the mains cord of the UPS to a working,

grounded AC wall socket outlet. The green LED

'LINE' will blink now: mains power is available and the

batteries are charging.

5.

For best results, allow the UPS to recharge the

batteries for a period of approx. 10 hours. It is

acceptable to use the UPS without first charging the

battery, but the runtime may be reduced.

6.

For advanced communication possibilities, the RS232

interface port (4) can be connected to a computer

system. See chapter 4.

ML 350-700

ML 1000

This manual is related to the following products: