Su m m it g as c on ve cti on o ve n – Garland SUMG100S1 User Manual
Page 2
Garland Commercial
Industries, LLC
185 East South Street
Freeland, PA 18224
Phone: (570) 636-1000
Fax: (570) 636-3903
Garland Commercial Ranges Ltd
1177 Kamato Road,
Mississauga, Ontario
L4W 1X4 CANADA
Phone: 905-624-0260
Fax: 905-624-5669
Enodis UK LTD
Swallowfield Way,
Hayes, Middlesex
UB3 1DQ ENGLAND
Telephone: 081-561-0433
Fax: 081-848-0041
“D”
TOP VIEW
38"
[965mm]
25-3/8"
[645mm]
54-9/16"
[1386mm]
3/4" N.P.T.
GAS INLET
3/4" REAR
GAS INLET
1" REAR
GAS INLET
7-3/4"
[197mm]
2"
[51mm]
3/4"
[19mm]
(includes
motor)
FLUE: 2-3/8" x 5"
[60mm x 127mm]
38-1/4"
[972mm]
11-1/2"
[292mm]
17-3/4"
[451mm]
1-1/4"
[32mm]
32-1/8"
[816mm]
34"
[864mm]
SINGLE DECK
FRONT VIEW
6-1/4"
[159mm]
DOUBLE DECK
FRONT VIEW
32-1/8"
[816mm]
32-1/8"
[816mm]
1-1/4"
[32mm]
32-1/8"
[816mm]
32-1/8"
[816mm]
14-3/4"
[375mm]
35-7/16"
[900mm]
Form# SUMG (06/07)
Su
m
m
it G
as
C
on
ve
cti
on
O
ve
n
Gas Input Ratings shown here are for installations up to
2,000 ft. (610m) above sea level. Specify altitudes over
2,000 ft.
Notes:
1. Standard electrical specifications include motor requirements.
2. (120V units) 115V, 3/4 HP, 2‑speed motor; 1140 and 1725 rpm, 60Hz.
3. (240V units) 200‑240V, 3/4 HP, 2‑speed motor; 1140 and 1725 rpm, 60 Hz
4. A 6 ft. line cord is provided for each 120V deck with a
(NEMA #5‑15P) plug.
5. U. S. Range recommends a separate 15 AMP circuit for each 120V unit.
Model
Int. Dimensions :In (mm)
Ext. Dimensions: In (mm)
Ship Wt
Ship Dim.
W
H
D
W
H **
D (w/motor)
Lbs/kg
Cubic Ft.
SUMG‑100S1
29 (736)
24 (610)
24 (610)
38 (965)
57‑1/2 (1461)
41‑1/4 (1048)
510/232
42
SUMG‑100D1
29 (736)
24 (610)
28 (711)
38 (965)
57‑1/2 (1461)
44‑1/2 (1130)
510/232
42
SUMG‑200S1
29(736)
24(610)
24(610)
38(965)
70‑1/2 (1791)
41‑1/4 (1048)
1024/464
84
SUMG‑200D1
29(736)
24(610)
28 (711)
38(965)
70‑1/2 (1791)
44‑1/2 (1130)
1024/464
84
** Height with or without standard casters. Height with low profile casters (double deck) is 68‑1/2" (1740mm).
Models
Input Ratings, Natural & Propane
Operating Pressure *
Electrical Specifications
BTU/hr
kW Equiv.
Gas Inlet
Natural
Propane
120V/1Ph.
240V/1Ph.
Single Deck
60,000
17. 6
(1 )@ 3/4" NPT
4.5" WC
(11 mbar)
10" WC
(25 mbar)
(1)@9.4A
(1)@ 5.2A
Double Deck
120,000
35.2
(1 )@1" NPT
(2)@9.4A
(2)@ 5.2A
*Maximum Pressure 13.8" WC @ 70°F (21°C)
Many local codes exist and it is the responsibility of the owner and installer to comply with those codes.
These appliances are intended for commercial use by professionally trained personnel.
Instillation Notes:
Combustible & Non-Combustible
Wall Clearances:
Sides
1" (25mm)
Back
3" (76mm)
Entry Clearances: In (mm)
Crated
44‑1/2 (1130) Uncrated 32‑1/2 (826)