Installation Instructions, Indoor Exhausting

6 ALCOVE OR CLOSET INSTALLATION

6 ALCOVE OR CLOSET INSTALLATION

• If your dryer is approved for installation in an alcove or

closet, it will be stated on a label on the dryer back.

• The dryer MUST be vented to the outdoors. See the

EXHAUST INFORMATION sections 3 & 4.

• Minimum clearance between dryer cabinet and adjacent

walls or other surfaces is:

3 in. front and rear

• Minimum vertical space from floor to overhead cabinets,

ceiling, etc. is 52 in.

• Closet doors must be louvered or otherwise ventilated and

must contain a minimum of 60 sq. in. of open area equally

distributed. If the closet contains both a washer and a

dryer, doors must contain a minimum of 120 sq. in. of open

area equally distributed.

7 BATHROOM OR BEDROOM

INSTALLATION

• The dryer MU ST be vented to the outdoors. See
EXHAUST INFORMATION section 3 & 4.
• The installation must conform with local codes or, in the
absence of local codes, with the NATIONAL ELECTRI-

CAL CODE, ANSI/NFPA NO. 70.

8 MOBILE OR MANUFACTURED

HOME INSTALLATION

• Installation must conform to the MANUFACTURED

HOME CONSTRUCTION & SAFETY STANDARD,

TITLE 24, PART 32-80 or, when such standard is not

applicable, with AMERICAN NATIONAL STANDARD

FOR MOBILE HOME, ANSI/NFPA NO. 501B.

• The dryer MUST be vented to the outdoors with the

termination securely fastened to the mobile home

structure. (See EXHAUST INFORMATION

section 3 & 4.)

• The vent MUST NOT be terminated beneath a mobile or

manufactured home.

• The vent duct material MUST BE METAL.

• Do not use sheet metal screws or other fastening devices

which extend into the interior of the exhaust vent.

• See section 2 for electrical connection information.

CONNECTING THE DRYER

TO HOUSE VENT

Rigid metal transitions ducts reduce the risk of crush-

ing and kinking.

Never install flexible metal duct in walls, ceilings, floors

or other enclosed spaces.

For best drying performance, a rigid metal transition

duct is recommended.

Avoid resting the duct on sharp objects.

In Canada and the United States, only the flexible

metal(foil-type) ducts that comply with the “Outline for

Clothes Dryer Transition Duct Subject 2158A” shall be

used.

For many applications, installing elbows at both the

dryer and the wall is highly recommended (see illustra-

tions below). Elbows allow the dryer to sit close to the

wall without kinking and or crushing the transition

duct, maximizing drying performance.

Total length of flexible metal duct should not exceed 8

feet (2.4m).

RIGID METAL TRANSITION DUCT

If rigid metal duct cannot be used, then UL-listed

flexible metal (semi-rigid) ducting can be used (Kit

WX08X10077).

UL-LISTED FLEXIBLE METAL (SEMI-RIGID) TRANSITION DUCT

In special installations, it may be necessary to connect

the dryer to the house vent using a flexible metal (foil-

type) duct. A UL-listed flexible metal (foil-type)duct

may be used ONLY in installations where rigid metal or

flexible metal (semi-rigid) ducting cannot be used AND

where a 4" diameter can be maintained throughout the

entire length of the transition duct.

Never install flexible metal duct in walls, ceilings, floors

or other enclosed spaces.

Total length of flexible metal duct should not exceed 8

feet (2.4m).

Avoid resting the duct on sharp objects.

For best drying performance:

1. Slide one end of the duct over the clothes dryer

outlet pipe.

2. Secure the duct with a clamp.

3. With the dryer in its permanent position, extend the

duct to its full length. Allow 2” of duct to overlap the

exhaust pipe. Cut off and remove excess duct. Keep

the duct as straight as possible for maximum airflow.

4. Secure the duct to the exhaust pipe with the other

clamp.

UL-LISTED FLEXIBLE METAL (FOIL-TYPE) TRANSITION DUCT

0 in. either side

ELBOWS HIGH

RECOMMENDED

ELBOW HIGH

RECOMMENDED

DO

DO NOT

CRUSH

FLEXIBLE

EXHAUST

AGAINST

WALL.

DO NOT

SIT DRYER

ON FLEXIBLE

EXHAUST.

DO NOT USE

EXCESSIVE

EXHAUST

LENGTH

DON’T