beautypg.com

Installation instructions – GE DCCD330EGWC User Manual

Page 4

background image

4

4 EXHAUST CONNECTION

5 LEVELING AND STABILIZING

YOUR DRYER

Installation Instructions

WARNING - TO REDUCE THE RISK

OF FIRE OR PERSONAL INJURY:

STANDARD REAR EXHAUST

(Vented at floor level)

STANDARD REAR EXHAUST

(Vented above floor level)

NOTE: ELBOWS WILL PREVENT DUCT
KINKING AND COLLAPSING.

STAND THE DRYER UPRIGHT NEAR THE FINAL LOCATION AND ADJUST

THE 4 LEVELING LEGS, AT THE CORNERS, TO ENSURE THAT THE DRYER

IS LEVEL FROM SIDE TO SIDE AND FRONT TO REAR.

NOTE: WE STRONGLY RECOMMEND SOLID METAL EXHAUST DUCTING.

HOWEVER, IF FLEXIBLE DUCTING IS USED IT

NOT PLASTIC.

MUST BE UL-LISTED METAL

This clothes dryer must be exhausted to the outdoors.

Use only 4” rigid metal ducting for the home exhaust

duct.

Use only 4” rigid metal or UL-listed flexible metal

(semi-rigid or foil-type) duct to connect the dryer to the

home exhaust duct. It must be installed in accordance

with the instructions found in “Connecting The Dryer

To House Vent” on page 5 of this manual.

Do not terminate exhaust in a chimney, a wall, a

ceiling, gas vent, crawl space, attic, under an enclosed

floor, or in any other concealed space of a building.

The accumulated lint could create a fire hazard.

Never terminate the exhaust into a common duct with

a kitchen exhaust system. A combination of grease and

lint creates a potential fire hazard.

Do not use duct longer than specified in the exhaust

length table. Longer ducts can accumulate lint,

creating a potential fire hazard.

Never install a screen in or over the exhaust duct. This

will cause lint to accumulate, creating a potential fire

hazard.

Do not assemble ductwork with any fasteners that

extend into the duct. These fasteners can accumulate

lint, creating a potential fire hazard.

Provide an access for inspection and cleaning of the

exhaust system, especially at turns and joints. Exhaust

system shall be inspected and cleaned at least once a year.

Do not obstruct incoming or exhausted air.

THIS DRYER COMES READY FOR REAR

EXHAUSTING. IF SPACE IS LIMITED, USE

THE INSTRUCTIONS IN SECTION 9 TO

EXHAUST DIRECTLY FROM THE SIDES OR

BOTTOM OF THE CABINET.

EXTERNAL

DUCT

OPENING

DUCT TAPE OR

DUCT CLAMP

DUCT TAPE OR

DUCT CLAMP

(CUT TO PROPER

LENGTH)

4" METAL DUCT

FOR STRAIGHT LINE INSTALLATION,

CONNECT THE DRYER EXHAUST TO

THE EXTERNAL EXHAUST HOOD

USING DUCT TAPE OR CLAMP.

RECOMMENDED

CONFIGURATION

TO MINIMIZE

EXHAUST

BLOCKAGE.

ELBOW HIGHLY

RECOMMENDED

ELBOW HIGHLY

RECOMMENDED

LEVEL

SIDE-TO-SIDE.

4 LEVELING

LEGS

LEVEL

FRONT-TO-BACK.