Installation Instructions

1 PREPARING FOR INSTALLATION

OF NEW DRYER

Minimum Clearance Other Than Alcove or Closet Installation

Minimum clearance to combustible surfaces and for air opening are: 0 in. clearance both sides and 1 in. rear. Consideration

must be given to provide adequate clearance for installation and service.

2 ELECTRICAL CONNECTION

INFORMATION

TIP: Install your dryer before installing your washer.

This will allow better access when installing dryer exhaust.

REMOVING LINT FROM WALL

EXHAUST OPENING

2

TILT THE DRYER SIDEWAYS

AND REMOVE THE FOAM

SHIPPING PADS BY

PULLING AT THE SIDES

AND BREAKING THEM

AWAY FROM THE DRYER

LEGS. BE SURE TO

REMOVE ALL OF THE

FOAM PIECES AROUND

THE LEGS.

• DO NOT USE AN EXTENSION CORD OR AN

ADAPTER PLUG WITH THIS APPLIANCE.

Dryer must be electrically grounded in accordance with

local codes and ordinances, or in the absence of local

codes, in accordance with the NATIONAL ELECTRI-

CAL CODE, ANSI/NFPA NO. 70.

WARNING - TO REDUCE THE RISK OF

FIRE, ELECTRICAL SHOCK AND PERSONAL

INJURY:

ELECTRICAL REQUIREMENTS

This dryer must be connected to an individual branch circuit,

protected by the required time-delay fuses or circuit breakers. A

four or three-wire, single phase, 120/240V or 120/208V, 60Hz,

30 amp circuit is required.

If the electric supply does not meet the above specifications, then

call a licensed electrician.

GROUNDING INSTRUCTIONS

This dryer must be connected to a grounded metal, permanent

wiring system, or an equipment-grounding conductor must be run

with the circuit conductors and connected to the equipment-

grounding terminal on the appliance.

L1

N
L2

RELOCATE GREEN

GROUND SCREW

HERE

STRAIN

RELIEF

BRACKET

GREEN OR

YELLOW WIRE

3/4", UL

RECOGNIZED

STRAIN RELIEF

HOT

WIRE

SCREWS

(3)

HOT

WIRE

COVER

NEUTRAL

(White)

REMOVE GROUND STRAP

AND DISCARD. KEEP GREEN

GROUND SCREW

4 #10 AWG MINIMUM COPPER

CONDUCTORS OR 120/240V 30A POWER

SUPPLY CORD KIT MARKED FOR USE

WITH DRYERS & PROVIDED WITH

CLOSED LOOP OR SPADE TERMINALS

WITH UPTURNED ENDS (NOT SUPPLIED).

INTERNAL DUCT

OPENING

CHECK THAT EXHAUST

HOOD DAMPER OPENS

AND CLOSES FREELY.

WALL

WARNING

:

Only a 4-conductor cord shall be used when the

appliance is installed in a location where grounding through the
neutral conductor is prohibited. Grounding through the neutral is
prohibited for the new branch-circuit installations, mobile homes,
recreational vehicles, and areas where local codes prohibit
grounding through the neutral conduction.

CONNECTING DRYER USING 4-WIRE

CONNECTION (MUST BE USED FOR

MOBILE HOME INSTALLATION)

NOTES: SInce January 1,1996, the National Electric code requires

that the new constructions utilize a 4-wire connection to

an electric dryer

Remove and discard existing plastic or metal foil

transition duct and replace with UL listed transition

duct.