Troubleshooting

309524L

17

Troubleshooting

Problem

Cause

Solution

Heater will not heat.

No current.

Check circuit and fuses.

Check continuity of primary thermo-
stat (24), backup thermostat (10),
and thermal limit sensor (15).

Check continuity of thermostat (10)
and heater block (3) terminals - Page
18.

Burned out heater block (3).

Replace block - Page 20.

Blown heat limiter (15).

Check continuity of primary thermo-
stat (24) and backup thermostat (10).
Replace thermostats if necessary
when replacing thermal limit sensor
(15) - Pages 18-20.

Temperature too low.

Fluid requires more warm-up time.

Increase warm-up time.

Wrong temperature setting.

Adjust setting - Page 15.

Flow rate too high.

Reduce flow rate or use 2 heaters.

Clogged fluid passages.

Flush regularly - Page 16.

Temperature too high.

Wrong temperature setting.

Adjust setting - Page 15.

Failed primary thermostat (24).

Replace - Page 18.

High fluctuating temperatures, about
220-250°F (104-120°C) at 0.1 GPM.

Primary thermostat (24) contacts
sticking.

Replace thermostats (24, 10) - Page
18. Note that backup thermostat (10)
keeps heater functioning for only a
short time.

Too much pressure drop or fluid will
not flow.

Flow rate too high.

Reduce flow rate or use 2 heaters.

Clogged fluid passages.

Flush regularly - Page 16.

Heater fittings leak.

Loose or damaged fittings.

Tighten fittings or replace heater
block - Page 20.