6.2 Subscriber Level Configuration Parameters
This section identifies the device-specific parameters, including registration and
authentication. These settings must be unique across devices in order to be matched with
the settings for a BroadWorks subscriber.
Provisioning a subscriber to register with BroadWorks allows calls to terminate to the
subscriber’s line. Registration requires that a unique address of record (AoR) is
provisioned on BroadWorks and the phone; provisioning an AoR on BroadWorks consists
of setting the line/port parameter to a unique value within the Application Server cluster.
Grandstream GXV-3000 / GXP-2000 / BT-200 supports three SIP accounts (lines), four
SIP accounts, and 1 SIP account respectively. The follow example shows how to
configure subscriber elements for an account.
Step
Command
Purpose
Subscriber Configuration Items
Step 1
Enable a line to be used.
Account Active = "Yes" ;
Enable a line of GXV-3000 / GXP-
2000 / BT-200 in use.
Step 2
Set Register User ID for a line.
Example:
SIP User_ID = "2405551111" ;
The register user ID must
correspond with the line/port
setting on BroadWorks.
Step 3
Enable SIP Authentication for a
line.
Example:
Authenticate ID =
"[email protected]" ;
Authenticate Password = "welcome"
;
If the Authentication service is
configured on BroadWorks, these
parameters must be configured to
match the BroadWorks settings.
Step 4
Configure display name for a
line.
Example:
Name = “Claire Smith” ;
For a line, configure the name to
be displayed on the device.