Goodman Mfg CPG SERIES User Manual

Page 23

background image

23

C

LEAN

O

UTSIDE

C

OIL

(Q

UALIFIED

S

ERVICER

O

NLY

)

The coil with the outside air flowing over it should be inspected
annually and cleaned as frequently as necessary to keep the
finned areas free of lint, hair and debris.

C

ONDENSER

, E

VAPORATOR

,

AND

I

NDUCED

D

RAFT

M

OTORS

Bearings on the air circulating blower motor, condenser mo-
tor and the combustion fan motor are permanently lubricated.
No additional oiling is required.

F

LAME

S

ENSOR

(Q

UALIFIED

S

ERVICER

O

NLY

)

A drop in the flame current can be caused by a nearly invis-
ible coating on the flame sensor. This coating, created by the
fuel or combustion air supply, can be removed by carefully
cleaning the flame sensor with steel wool.

NOTE: After cleaning, the microamp signal should be stable
and in the range of 4 - 6 microamps DC.

F

LUE

P

ASSAGES

(Q

UALIFIED

S

ERVICER

O

NLY

)

At the start of each heating season, inspect and, if neces-
sary, clean the unit flue passage.

L

UBRICATION

The fan shaft bearings, the 1 to 2 HP supply fan motors the
condenser fan motors and compressors are permanently lu-
bricated.

I

NSPECTION

& C

LEANING

All flue product carrying areas of the furnace, its vent sys-
tem, and main burners should be examined by a qualified
service agency before the start of each heating season. This
examination is necessary for continued safe operation. Par-
ticular attention should be given to deterioration from corro-
sion or other sources. This examination is accomplished in
the following manner.

1. Disconnect power to the unit and remove furnace

section access panel.

2. Remove burner assembly:

a. Disconnect the three wires from the gas valve after

noting which wires are connected to each terminal.

b. Disconnect wires from the flame rod and ignition

electrode.

c. Disconnect the gas piping at the union.
d. The entire burner assembly can now be removed

from the unit.

NOTE: Use all screws that were removed; they are
necessary for safe and proper operation of the unit.

3. Inspect and periodically clean the vent outlet (bird

screen) on the access panel.

NOTE: Periodic observation of the flame and a log of C0

2

measurements are recommended. This will aid in determining
whether the furnace is operating efficiently or if the furnace
requires cleaning.

Flames should be stable, soft and blue (dust may cause or-
ange tips but must not be yellow). The flames must extend
directly outward from the burner without curling, floating or
lifting off.

BURNER FLAME

T

O

 

AVOID

 

PERSONAL

 

INJURY

 

OR

 

DEATH

 

DUE

 

TO

 

ELECTRIC

 

SHOCK

DO

 

NOT

 

REMOVE

 

ANY

 

INTERNAL

 

COMPARTMENT

 

COVERS

 

OR

 

ATTEMPT

 

ANY

 

ADJUSTMENT

. C

ONTACT

 

A

 

QUALIFIED

 

SERVICER

 

AT

 

ONCE

 

IF

 

AN

 

ABNORMAL

 

FLAME

 

SHOULD

 

DEVELOP

.

WARNING

At least once a year, prior to or during the heating season,
make a visual check of the burner flames.

NOTE: This will involve removing and reinstalling the heat
exchanger door on the unit, which is held by two screws. If
you are uncertain about your ability to do this, contact a
qualified servicer.

If a strong wind is blowing, it may alter the airflow pattern
within the unit enough that an inspection of the burner flames
is not possible.

F

UNCTIONAL

P

ARTS

Refer to the unit Parts Catalog for a list of functional parts.
Parts are available from your distributor.