Troubleshooting

The following pages are provided to help determine the cause of problems with operation of the brewers and to
indicate the appropriate solution for the problems. For each problem, the possible causes should be checked in
the order shown until the exact nature of the problem is determined.

The following procedures must be performed by a qualified service technician. Disconnect power to
machine before servicing.

Error Messages

Problem

Possible Causes

Service Check

Remedy

ER1

• Fill valve on for over

6 min. (This occurs
during initial fill on some
units – see Initial
Start-up
.)

• Check system for

water leaks.

• Correct any leaks and reset

controller.

ER2

• Thermistor failure or

loose connections in
thermistor circuit.

• Ensure that connector

is securely attached to
controller and that

thermistor is securely
connected.

• Secure connections and reset

controller. If error reoccurs,
replace thermistor.

ER3

• Thermistor is reading

out of range.

• Check tank

temperature.

• Replace thermistor.

ER4

• No heat is detected

• See Heating Problems

• See Heating Problems

Filling Problems

Problem

Possible Causes

Service Check

Remedy

Overfilling water
tank when power
is Off

• Fill valve not sealing

properly.

• Check to see if water

enters tank continuously
(usually at a slow rate).

• Disassemble valve and clean

out debris. Valve may need to
be replaced.

Overfilling water
tank only when
power is On

• High electrode coated

with lime or faulty.

• Connection from

control board to tank
body faulty.

• Control board is faulty.

• Disconnect electrode

wire at quick connect
(brown wire). Connect a
wire from the quick con-
nect to the cabinet body.
If filling stops, this is the
error cause.

• Check to ensure

connection (red
wire) is secure.

• Secure connection from

control board to metal
enclosure does not
stop filling.

• Remove electrode assembly

and clean the probes. If
problem is not corrected,
replace electrode assembly.

• Make connection to tank

secure.

• Replace control board.