beautypg.com

Notice, Blower housing and intake barrel assemblies – Grizzly G0637 User Manual

Page 22

background image

-20-

G0637/G0638 Cyclone Dust Collector

4. With assistance, place the intake barrel over

the large cyclone funnel and align the mount-
ing holes as illustrated in

Figure 17.

NOTICE

When connecting parts that have a gasket

applied to the mounting surface, always

tighten the fasteners in a diagonal and rota-

tional manner to ensure the gasket does not

become crimped and compromise the seal.

������

������

�������������

������

��������������

�����

��

�����

Figure 17. Intake barrel and large cyclone funnel

mounting holes aligned.

6. Install the four cyclone mounting brackets

with (8)

5

16

"-18 x 1

1

4

" hex bolts, (16)

5

16

"

flat washers, and (8)

5

16

"-18 hex nuts (see

Figures 17 & 19).

5. Connect the intake barrel and large cyclone

funnel with (12)

5

16

"-18 x 1

1

4

" hex bolts, (24)

5

16

" flat washers, and (12)

5

16

"-18 hex nuts in

the mounting holes—excluding the left and
right hole of the groups of three (see

Figure

18).

Figure 19. Cyclone mounting bracket mounted

to collector assembly.

Figure 18. Intake barrel and large cyclone

funnel.

Large Cyclone

Funnel

Intake

Barrel

Blower Housing and Intake Barrel

Assemblies

1. Apply the 3 x 6 x 2500mm gasket to the top

mating surface of the intake barrel assem-
bly.

2. Keeping the intake barrel assembly on the

floor, lower the blower housing assembly
over and approximately one inch away from
the intake barrel assembly.

3. Using two punches or Phillips screwdrivers

as alignment guides (see

Figure 20), lower

the blower housing assembly onto the intake
barrel assembly.

Figure 20. Aligning the mounting holes.

Outlet

Port