Notice, Blower housing and intake barrel assemblies – Grizzly G0637 User Manual
Page 22
-20-
G0637/G0638 Cyclone Dust Collector
4. With assistance, place the intake barrel over
the large cyclone funnel and align the mount-
ing holes as illustrated in
Figure 17.
NOTICE
When connecting parts that have a gasket
applied to the mounting surface, always
tighten the fasteners in a diagonal and rota-
tional manner to ensure the gasket does not
become crimped and compromise the seal.
������
������
�������������
������
��������������
�����
��
�����
Figure 17. Intake barrel and large cyclone funnel
mounting holes aligned.
6. Install the four cyclone mounting brackets
with (8)
5
⁄
16
"-18 x 1
1
⁄
4
" hex bolts, (16)
5
⁄
16
"
flat washers, and (8)
5
⁄
16
"-18 hex nuts (see
Figures 17 & 19).
5. Connect the intake barrel and large cyclone
funnel with (12)
5
⁄
16
"-18 x 1
1
⁄
4
" hex bolts, (24)
5
⁄
16
" flat washers, and (12)
5
⁄
16
"-18 hex nuts in
the mounting holes—excluding the left and
right hole of the groups of three (see
Figure
18).
Figure 19. Cyclone mounting bracket mounted
to collector assembly.
Figure 18. Intake barrel and large cyclone
funnel.
Large Cyclone
Funnel
Intake
Barrel
Blower Housing and Intake Barrel
Assemblies
1. Apply the 3 x 6 x 2500mm gasket to the top
mating surface of the intake barrel assem-
bly.
2. Keeping the intake barrel assembly on the
floor, lower the blower housing assembly
over and approximately one inch away from
the intake barrel assembly.
3. Using two punches or Phillips screwdrivers
as alignment guides (see
Figure 20), lower
the blower housing assembly onto the intake
barrel assembly.
Figure 20. Aligning the mounting holes.
Outlet