Iring, Iagram, Warning – Goodman Mfg GDS8 User Manual
Page 11: The goodman manufacturing company,l.p, Label, wiring diag. - mini, Roduct, Pecifications

10
www.goodmanmfg.com
SS-GMS8
SS-GMS8
www.goodmanmfg.com
11
P
roduct
S
PecificationS
P
roduct
S
PecificationS
w
irinG
D
iaGraM
0140F00119
CC
SC
9
8
7
6
5
4
3
2
1
9
8
7
6
5
4
3
2
1
F
C
D
E
B
A
F
C
D
E
B
A
(6.000)
(10.750)
THE GOODMAN MANUFACTURING COMPANY,L.P.
DRAWING TO BE INTERPRETED IN
ACCORDANCE WITH ASME Y14.100
TITLE
LABEL, WIRING DIAG. - MINI
DIMENSIONS ARE IN INCHES
UNLESS OTHERWISE NOTED.
TOLERANCES:
ANGLES
1.5
.X
.1
.XX
.03
.XXX
.015
HOLES
:
.005
TUBE CUT LG:
.063
DWN: VANL
ENG:R. ROBERTS
SCALE: NTS
DATE: 10-22-04
CHK: RSR
SHEET: 1
OF
1
DWG.
NO.
0140F00119
A
SPECIAL CHARACTERISTICS:
= 6SIGMA = CRITICAL CHARACTERISTIC = SIGNIFICANT CHARACTERISTIC
COMPONENTS AND MATERIALS SPECIFIED HEREIN WILL ALSO CONFORM TO THE APPLICABLE SECTION OF
GOODMAN MSP 824.01 WORKMANSHIP STANDARD FOR FIT, FEEL, AND FINISH.
CONFIDENTIAL PROPERTY OF THE GOODMAN FAMILY OF COMPANIES NOT TO BE DISCLOSED TO OTHERS, COPIED, OR USED FOR ANY PURPOSE
EXCEPT AS AUTHORIZED IN WRITING. MUST BE RETURNED UPON DEMAND, ON COMPLETION OF ORDER, OR OTHER PURPOSE FOR WHICH IT WAS LENT.
ECN
REV
ZONE
DESCRIPTION
CHK
DR
DATE
0903235
A
-
D7
A9
UPDATED FORMAT
CORRECTED SPELLING OF AUXILIARY
REMOVE NOTE4, SUPPLIER TO ADVISE.....
GL
01-30-09
CAP
B
K
(
H
I
)
AUXILIARY
INTEGRATED
PROPERLY POLARIZED AND GROUNDED.
SERVICING.WIRING TO UNIT MUST BE
WARNING:DISCONNECT POWER BEFORE
24 VAC
FUSE
G
C
6
3
9
12
HUMIDIFIER
W
Y
R
R
5
4
1
2
8
7
11
10
OR
LED
DIAGNOSTIC
LINE-H XFMR-H HEAT-H COOL-H
CONTROL MODULE
BK
115 VAC HOT AND PARK TERMINALS
2
1
GR
PU
XFMR
B
K
BK
BK
115V
24V
115
VAC
NEUTRAL
BR
LIMITS
WH
W
H
(
N
)
R
D
(
L
O
W
)
O
R
(
M
E
D
L
O
W
)
B
L
(
M
E
D
)
C
I
C
U
L
A
T
O
R
B
L
O
W
E
R
24V THERMOSTAT CONNECTIONS
RO2 (11)
LIMIT
GND (8)
HUMIDIFIER
XFMR (6)
GND
G
C
W
Y
TO
MICRO
R
MV (12)
MVC (9)
AUXILIARY
LIMIT CONTROLS
PS (10)
PSO (4)
HLI (7)
HLO (1)
CONTROL MODULE
INTEGRATED
NO
SWITCH
PRESSURE
ID BLOWER
VALVE
M1
GAS
C2
C
AUTO RESET
PRIMARY
MANUAL RESET ROLLOUT
LIMIT CONTROL(S)
115 VAC
FLAME SENSOR
FP (2)
XFMR-H
XFMR (3)
RO1 (5)
24 VAC
HOT SURFACE
IGNITER
I
N
T
E
G
R
A
T
E
D
C
O
N
T
R
O
L
M
O
D
U
L
E
BR
B
R
COOL-H
IGN
IND
ID
BLWR
CIRCULATOR
HEAT-H
COOL
HEAT
BLWR
TRANSFORMER
40 VA
CONTROL
XFMR-N
I
N
T
E
G
R
A
T
E
D
C
O
N
T
R
O
L
M
O
D
U
L
E
CIR-N
0140F00119 REV.A
5. UNIT MUST BE PERMANENTLY GROUNDED AND CONFORM TO N.E.C. AND LOCAL CODES.
ON SOME MODELS
HUMIDIFIER
24 VAC
INDUCED DRAFT
C. USE COPPER CONDUCTORS ONLY.
BLOWER COMPARTMENT
BURNER COMPARTMENT
REPLACED, IT MUST BE REPLACED WITH WIRING MATERIAL HAVING A TEMPERATURE
3. IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE FURNACE MUST BE
CORRECT COOLING CFM. (SEE SPEC SHEET FOR AIR FLOW CHART)
REQUIREMENTS SO AS TO PROVIDE THE CORRECT HEATING TEMPERATURE RISE AND THE
4. BLOWER SPEEDS SHOULD BE ADJUSTED BY INSTALLER TO MATCH THE INSTALLATION
INTEGRATED CONTROL
INTERNAL TO
2. MANUFACTURER'S SPECIFIED REPLACEMENT PARTS MUST BE USED WHEN SERVICING.
1. SET HEAT ANTICIPATOR ON ROOM THERMOSTAT AT 0.7 AMPS.
BLOWER
GAS VALVE
PRIMARY LIMIT
B
K
GR
WH
IGNITER
SURFACE
HOT
M1
PU
WH
RD
WH
15 PIN PLUG
C
NO
SWITCH
PRESSURE
BR
C2
SENSOR
FLAME
BK
WH
ROLLOUT LIMITS
RAPID FLASHES = REVERSED 115 VAC POLARITY/VERIFY GND
SYSTEM LOCKOUT (RETRIES/RECYCLES EXCEEDED)
7 FLASHES = LOW FLAME SIGNAL
5 FLASHES = FLAME SENSE WITHOUT GAS VALVE
4 FLASHES = OPEN HIGH LIMIT
3 FLASHES = PRESSURE SWITCH STUCK OPEN
2 FLASHES = PRESSURE SWITCH STUCK CLOSED
STEADY ON = NORMAL OPERATION
OFF = CONTROL FAILURE
5
1 FLASH =
0
1
2
3
4
PU
6 FLASHES =
OPEN ROLLOUT
COLOR CODES:
PU PURPLE
OR ORANGE
YL YELLOW
6
7
C
BK BLACK
GR GREEN
BR BROWN
PK PINK
RD RED
GY GRAY
BL BLUE
WH WHITE
PU
RATING OF AT LEAST 105
NOTES:
TO 115VAC/ 1Ø /60 HZ POWER SUPPLY WITH
OVERCURRENT PROTECTION DEVICE
JUNCTION BOX
MUST BE
WARNING:
SWITCH
WIRING TO UNIT
BEFORE SERVICING.
DISCONNECT POWER
LINE-H
DOOR
AND GROUNDED.
POLARIZED
PROPERLY
L
GND
LINE-N
DISCONNECT
N
SWITCH (TEMP.)
FIELD SPLICE
SWITCH (PRESS.)
PROT. DEVICE
OVERCURRENT
EQUIPMENT GND
TERMINAL
JUNCTION
HI VOLTAGE FIELD
HI VOLTAGE (115V)
LOW VOLTAGE FIELD
LOW VOLTAGE (24V)
PLUG CONNECTION
IGNITER
FIELD GND
IND-N
IGN-N
JUNCTION
BOX
OVERCURRENT PROTECTION
POWER SUPPLY WITH
TO 115 VAC/ 1/60HZ
GND
LINE-N
LINE H
DEVICE
DOOR SWITCH
WH
BK
SWITCH LOCATED IN BLOWER
COMPARTMENT ON SOME MODELS
RD
RD
R
D
BL
YL
YL
RD
B
L
BL
PU
YL
YL
BR
OR
OR
OR
Y
L
YL
R
D
R
D
W
H
W
H
WH
YL
O
R
B
K
YL
BR
WH
(SINGLE CONTROL ON SOME MODELS)
(SINGLE CONTROL ON SOME MODELS)
NOTES:
1. MATERIAL: 20lb WHITE BOND PAPER WITH PERMANENT PRESSURE SENSITIVE ADHESIVE.
LABEL TO HAVE REMOVABLE PAPER BACKING, SLIT ON BACKING FOR EASY REMOVAL.
2. COLOR: BLACK PRINTING ON WHITE BACKGROUND.
3. REVISION NUMBER ON DIAGRAM REMAINS UNCHANGED UNTIL THE DIAGRAM PROPER IS CHANGED.
4. REMOVED NOTE.
A
Wiring
is
subject
to
chang
e.
Alw
ay
s
re
fer
to the wiring diagr
am or the
unit
for the mos
t up-t
o-da
te
wiring.
⚠
W
arning
High
Volt
ag
e:
Disc
onn
ect
all
po
w
er
be
for
e
ser
vicing
or
in
st
alling
this
unit.
Multiple
po
w
er
sour
ces
ma
y
be
pr
esen
t.
Failur
e
to
do
so
ma
y
cause
pr
operty
damag
e,
per
sonal
injur
y,
or
dea
th.
⚡