2 refilling jib oil systems – Frymaster 14 Series User Manual
Page 36

4-18
The computer displays
cln vat Complete.
8. Clean the vat with a scrub brush and when complete press the (1
yes)
button to continue (see Figure 62).
Figure 62
The drain valve closes and the vat is ready to be refilled with oil.
4.10.4.2 Refilling JIB Oil Systems
JIB (Jug In Box) oil systems use oil stored in boxed jugs inside the fryer cabinet.
If the oil system was set to JIB during initial setup, the computer displays
manual fill pot.
1. Carefully pour oil into the pot until it reaches the low fill line in the fryer.
2. Press the (1
yes) button (see Figure 63) when vat is full.
The computer displays
off.
Figure 63
4.10.4.3 Draining and Disposing Oil using Bulk Oil Systems
Bulk oil systems use pumps to move the oil from the fryer to holding tanks for fresh and exhausted
oil. Additional plumbing is used to connect the bulk oil systems to the fryers.
1. With the computer
OFF, press and hold the FLTR button of the
corresponding vat for three seconds (see Figure 64).
Computer displays
fltr menu for three seconds changing to Auto
Filter.
2. Press the
u (INFO) button (see Figure 65) and scroll to dispose .
3. With
dispose displayed, press the (1 yes) button to continue (see
Figure 66).
The computer display alternates between
Dispose and Yes NO.
If
CHK PAN is displayed, remove and replace the filter pan, ensuring that the
pan is seated firmly into the fryer.
4. To dispose press the
(1 yes) button to continue (see Figure 67).
Figure 64
Figure 65
Figure 66
Figure 67
The drain valve remains open and the computer displays
Vat empty
alternating with
yes no.
5. When the vat is empty, press the (1
yes) button to continue (see Figure
68).
Figure 68
The computer displays
cln vat Complete.