beautypg.com

Specifications, Electrical, Plumbing – Follett HCC1400W User Manual

Page 5: Ambient, Heat rejection, Ice production

background image

5

Specifications

Electrical

Each icemaker requires its own separate circuit with electrical disconnect within 10 ft (6m).
Equipment ground required.
Standard electrical – 208-230/60/1
Maximum icemaker fuse – 20 amps each
Amperage – 12 amps
6 ft (2m) NEMA 6-20 cord and plug provided on icemaker

Plumbing

3/8" OD push-in water inlet
3/4" MPT drain
1/4" FPT condenser inlet (water-cooled condenser only)
1/4" FPT condenser drain (water-cooled condenser only)

Notes: 3/4" vented drain line must slope a minimum of 1/4" per foot (6mm per 30.4cm run).

Drain to be hard piped and insulated.

To prevent back flow, do not connect drains.

Separate drains for icemaker and condenser.

Water shut-off recommended within 10 feet (3m).

Follett recommends installation of a Follett water filter system (part# 00130286) in icemaker inlet

water

line.

Ambient

Air temperature

100˚F/38˚C max.

50˚F/10˚C min.

Water temperature

90˚F/32˚C max.

45˚F/7˚C min.

Water pressure – potable

70 psi max. (483 kPa)

10 psi min. (69 kPa)

Note: Water-cooled condenser pressure 150 psi (1034 kPa)

Heat rejection

Air-cooled rejects 14,500 BTU/hr to air
Water-cooled rejects 14,500 BTU/hr to water

Ice production

F

C

50

10

60

16

70

21

80

27

90

32

60

16

1591

722

1509

684

1396

633

1364

619

1270

576

70

21

1454

660

1374

541

1270

576

1267

575

1169

530

80

27

1315

596

1197

543

1178

534

1129

512

1071

486

90

32

1187

538

1127

511

1068

484

1020

462

969

440

100

38

1056

479

1030

467

932

423

902

409

870

395

lbs

kg

lbs

kg

lbs

kg

lbs

kg

lbs

kg

Inlet W

a

ter T

emper

atur

e F/C

Ambient Air Temperature F/C

Air-cooled icemaker capacity/24 hrs.

F

C

50

10

60

16

70

21

80

27

90

32

60

16

1356

615

1272

577

1160

526

1065

483

999

453

70

21

1356

615

1272

577

1160

526

1065

483

999

453

80

27

1356

615

1272

577

1160

526

1065

483

999

453

90

32

1356

615

1272

577

1160

526

1065

483

999

453

100

38

1356

615

1272

577

1160

526

1065

483

999

453

lbs

kg

lbs

kg

lbs

kg

lbs

kg

lbs

kg

Water-cooled icemaker capacity/24 hrs.

Inlet W

a

ter T

emper

atur

e F/C

Ambient Air Temperature F/C