Refrigeration system – Follett HCC1400W User Manual
Page 23
23
thermostatic
expansion
valve
compressor
High pressure vapor
High pressure liquid
Low pressure liquid
Low pressure vapor
low side
service port
high side
service port
condenser
filter dryer
high side
refrigeration
line run
low side
refrigeration
line run
Refrigeration system diagram
Air-cooled condensers (air)
50˚F/10˚C 60˚F/16˚C 70˚F/21˚C 80˚F/27˚C 90˚F/32˚C 100˚F/38˚C
Pressure (psig)
discharge/suction
190/25
217/29 241/29 276/32 317/36 358/39
Water-cooled condensers (water) 50˚F/10˚C 60˚F/16˚C 70˚F/21˚C 80˚F/27˚C 90˚F/32˚C
Pressure (psig)
discharge/suction
235/21
237/21 238/20 236/21 315/33
Note:
The water control valve is factory set to maintain 238 ± 15 psi discharge pressure @ 70˚ F water.
Refrigeration system
Refrigerant pressure data
This manual is related to the following products: