Specifications, Electrical, Electrical connections plumbing – Follett T400A/W User Manual
Page 5: Ambient
5
Specifications
Electrical
Each icemaker and dispenser require a separate circuit with electrical disconnect within 10 ft (6m).
Equipment ground required.
Standard electrical – 115V, 60Hz, 1 phase.
Maximum dispenser fuse – 15 amps,
Maximum icemaker fuse – 20 amps each
Maximum icemaker amperage – 11 amps each
Cord and plug provided on icemaker and dispenser
Model
Electrical connection
Circuits required
25FB400A/W, 50FB400A/W, 110FB400A/W
cord & plug provided
115/60/1, 20 amp max. fuse size
25CT400A/W, 50CT400A/W, 110CT400A/W
cord & plug provided
115/60/1, 20 amp max. fuse size
25CR400A/W, 50CR400A/W, 110CR400A/W
dispenser, icemaker
115/60/1, (2) circuits required
and bin signal:
dispenser: 15 amp max. fuse size
cord & plug provided
icemaker: 20 amp max. fuse size
VU155R400A/W, VU300R400A/W
dispenser, icemaker
115/60/1, (2) circuits required
VU155BR400A/W, VU300BR400A/W
and bin signal:
dispenser: 15 amp max. fuse size
VU155R400A/WX, VU155BR400A/WX
cord & plug provided
icemaker: 20 amp max. fuse size
VU155NR400A/W, UD300R400A/W
dispenser, icemaker
115/60/1, (3) circuits required
VU155R800A/W, VU300R800A/W,
and bin signal:
VU155R800A/WX,
cord & plug provided
dispenser: 15 amp max. fuse size
VU155BR800A/W, VU300BR800A/W,
(2) icemakers: 20 amps max. fuse
VU155R800A/WX
size
each
Electrical connections
Plumbing
3/8" OD push-in water inlet
3/4" MPT drain
3/8" FPT condenser inlet (water-cooled condenser only)
3/8" FPT condenser drain (water-cooled condenser only)
Notes: Slope to drain of 1/4" per foot (6mm per 30.4cm run) with a 1/2" min. is recommended.
Water shut-off recommended within 10 feet (3m), drain to be hard piped and insulated.
Separate drains for icemaker and condenser. To prevent back flow, do NOT connect drains.
Follett recommends installation of an activated carbon filter in icemaker inlet water line.
Ambient
Air temperature
100˚ F/38˚ C max.
50˚F/10˚C min. (best performance below 80˚F/27˚C)
Water temperature
90˚F/32˚C max.
40˚F/4˚C min. (best performance below 70˚F/21˚C)
Water pressure
70 P.S.I max. (482 kPA)