Technical specifications (all models), Air-cooled icemaker refrigeration pressure, Water-cooled icemaker refrigeration pressure – Follett T400A/W User Manual
Page 19
condenser
filter dryer
thermostatic
expansion
valve
evaporator
high side
service port
low side
service port
high pressure
switch
compressor
high
pressure
vapor
low
pressure
vapor
high
pressure
liquid
low
pressure
liquid
19
Technical specifications (all models)
Refrigeration system diagram
Refrigeration pressure data
Notes: 1) Water regulating valve is factory set at 225 PSIG head pressure.
2) Readings within 10% of above table values should be considered normal.
Ambient air temperature ˚F/˚C
Icemak
er inlet w
ater temper
ature ˚F/˚C
˚F/˚C
50/10
70/21
90/32
60/16
174/23
174/23
190/25
80/27
245/31
244/30
265/32
100/38
237/37
326/38
347/40
Air-cooled Icemaker
Refrigeration Pressure
Discharge Pressure/Suction Pressure
psi
psi
psi
Condenser inlet water temperature ˚F/˚C
Icemak
er inlet w
ater temper
ature ˚F/˚C
˚F/˚C
50/10
70/21
90/32
50/10
236/28
237/28
236/28
70/21
235/29
230/30
235/30
90/32
250/34
250/34
250/34
Water-cooled Icemaker
Refrigeration Pressure
Discharge Pressure/Suction Pressure
psi
psi
psi
Compressor data
Compressor current draw
Air-cooled
Ambient air temp.
60˚F/15.6˚C
70˚F/21.1˚C
80˚F/26.7˚C
90˚F/32.2˚C
100˚F/37.8˚C
6.3A 6.5A 6.7A 6.9A 7.1A
Water-cooled
Water temp. at float
50˚F/10˚C
60˚F/15.6˚C
70˚F/21.1˚C
80˚F/26.7˚C
90˚F/32.2˚C
6.6A 6.7A 6.7A 6.8A 6.9A
Locked rotor amps 58.8