Installation requirements – Fire Magic ECHELON E660 User Manual

Page 10

background image

10

REV 1 - 0809031556

L-C2-28708

INSTALLATION REQUIREMENTS

This grill is designed for outdoor use only. DO NOT use this grill under unprotected fl ammable

surfaces. DO NOT use this grill inside a building, garage, enclosed area, or an unprotected covered

area (see EXHAUST REMOVAL below). DO NOT use this grill in or on a recreational vehicle or boat.

IMPORTANT: This grill is NOT insulated, and therefore the unit, when in operation, must be located with

a minimum of 20" (50.7 cm) of side and back clearance from unprotected combustible
materials such as wood, plastic, or stucco with wood framing.

The control panel MUST remain removable for
servicing and air shutter adjustment (see PARTS
LIST).

ENSURING PROPER COMBUSTION AIR AND
COOLING AIRFLOW

Proper airfl ow (Fig. 10-1) MUST be maintained for
the grill to perform as it was designed. If airfl ow
is blocked, overheating and poor combustion will
result. Do not block the 1" (2.5 cm) front air inlet
along the bottom of the control panel or more
than 75% of the cooking grid surface with pans
or griddles.

Note: The 1" (2.5 cm) front air space also allows

access to the drip tray.

EXHAUST REMOVAL

If installed or used under a patio roof, the cooking
grid area must be fully covered by an exhaust hood
with a chimney. An exhaust fan with a rating of
1,000 CFM (cubic feet per minute) (472 liters per
second) or more may be necessary to effectively
remove smoke and other cooking by-products from
the area under the hood. This outdoor grill must not
be used under unprotected overhead combustible
construction. THIS UNIT MUST NOT BE LOCATED
IN A FULLY ENCLOSED AREA OF ANY KIND.

Fig. 10-1

- Ventilation

CAUTION: Wind blowing into or across the rear

oven lid vent (Fig. 10-2) can cause
poor performance and/or dangerous
overheating. Orient the grill so that the
prevailing wind blows toward the front
of the grill (Fig. 10-3).

CAUTION: To prevent dangerous overheating, the

rear of the unit must have a minimum
clearance of 8" (20.3 cm) from any
backsplash/wall.

GAS SUPPLY AND MANIFOLD PRESSURES:
For natural gas - normal 7" (17.78 cm) water column
(w.c.), minimum 5" (12.7 cm), maximum 10

1

/

2

" (26.7

cm). For propane gas - normal 11" w.c., minimum 10"
(25.4 cm), maximum 13" (33 cm).

Fig. 10-3

CORRECT

PLACE GRILL SO PREVAILING WIND

BLOWS TOWARD FRONT OF GRILL

YOU MUST PROTECT REAR OVEN

VENT FROM PREVAILING WIND

Rear oven lid vent

INCORRECT

Fig. 10-2

This manual is related to the following products: