Frymaster Dean 1824E User Manual
Page 9
1-6
12. Thread the new probe wire through the
hole in front of the fryer. The probe
assembly should be oriented in the same
manner as the probe being replaced. Place
the new probe assembly onto the element,
and ensure that the probe extends 1”
beyond the front of the bracket before
securing the bracket. Also ensure that the
springs are on each probe under each
bracket.
13. Apply Loctite PST567 sealant to
replacement threads.
14. Screw the replacement probe into the
frypot and tighten 170-180 inch-pounds
torque. DO NOT OVERTIGHTEN.
15. Reattach the connector and reassemble in
reverse order.
1.11 Replace Heating Elements inside Frypot
1. Perform Procedure 1.10, Replace
Temperature Probe, Steps 1-9.
2. Remove the four screws from the two
brackets in the rear of the frypot that
secure the element to the frypot.
3. Remove wires from the elements by
loosening and removing the nuts.
4. Remove element using an open-end
wrench or other suitable tool to loosen the
compression fitting.
5. Gently remove the element by sliding out into the frypot and lifting up as you remove it.
6. Insert new element and reassemble in reverse order.
High-Limit Thermostat
Temperature
Sensor
Remove screws here.