beautypg.com

Frymaster Dean 1824E User Manual

Page 15

background image

1-12

1.17.2 Filtration Problems

Problem

Probable Causes

Corrective Action

A. Power cord is not plugged in or circuit

breaker is tripped.

A. Verify that the power cord is fully

plugged in. If so, verify that circuit
breaker is not tripped.

Filter pump won't

start.

B. Blockage in filter pump.

Test: Close the drain valve and pull
the filter pan out from the fryer.
Activate the pump. If the pump motor
hums for a short time then stops, the
probable cause is blockage of the
pump itself.

B. Pump blockages are usually caused

by sediment buildup in the pump
due to improperly sized or installed
filter paper and failure to use the
crumb screen.