Installation, Installation warnings, Packing list – FireplaceXtrordinair 44 DV XXL EF User Manual
Page 7: Additional items required
Installation
(for qualified installers only)
7
Travis Industries
4050114
1 0 0 - 0 1 1 4 9
Installation Warnings:
!
Failure to follow all of the requirements may result in property damage, bodily injury, or
even death.
!
This heater must be installed by a qualified installer who has gone through a training
program for the installation of direct vent gas appliances.
!
This appliance must be installed in accordance with all local codes, if any; if not, in
U.S.A. follow ANSI Z223.1 and NFPA 54(88).
!
In Manufactured or Mobile Homes must conform with: In USA, Manufactured Home
Construction and Safety Standard, Title 24 CFR, Part 3280. This appliance may be
installed in Manufactured Housing only after the home is site located.
!
The 44 DV XXL is designed to operate on natural gas or propane (LP).
!
All exhaust gases must be vented outside the structure of the living-area. Combustion
air is drawn from outside the living-area structure.
!
Notify your insurance company before hooking up this fireplace.
!
The requirements listed below are divided into sections. All requirements must be met
simultaneously. The order of installation is not rigid – the qualified installer should
follow the procedure best suited for the installation.
Packing List
•
Propane Conversion Kit
•
Log Set (Log Set, Coals, & Glowing Embers)
•
Flex Tube with Pipe Adapter
•
Glass Latch Key (to un-latch glass frame)
•
Arch Covers (for arched face)
•
Firestop (manufactured for the 44 DV XXL)
•
(2) Fireback Clips (for ceramic firebacks only)
Additional Items Required
•
Faceplate - Includes attachment screws
•
Direct Vent (Simpson Dura-Vent Ph. # 800 835-4429)
•
Gas Line Equipment (shutoff valve, pipe, etc.)
•
Electrical Equipment (min. 18 gauge, grounded line)