Installation, Hearth requirements, Floor mounted fireplaces raised fireplaces – FireplaceXtrordinair 44 DV XXL EF User Manual
Page 22
2 2
Installation
(for qualified installers only)
Travis Industries
4050114
1 0 0 - 0 1 1 4 9
Hearth Requirements
6-1/4"
Do not build the hearth
above this ledge.
12” Min.
53" Min.
Cement Board
(required)
Tile, Marble, Brick, or
other Non-Combustible
Decorative Trim
(may be combustible)
Min. 3/4”
Max. 15/16”
Floor Mounted
Fireplaces
Raised
Fireplaces
When raised a minimum of 3”
off of the floor surface, no
hearth is required.
Make sure to accomodate the floor covering (carpet, linoleum,
flooring, etc.) when determining the height of the fireplace stand (i.e.
the thicker the carpet, the taller the fireplace stand).
Fireplace
Stand
6-1/4"