Installation

(for qualified installers only)

1 1

Travis Industries

4050114

1 0 0 - 0 1 1 4 9

Corner Installations

A typical 45° installation uses the minimum framing dimensions shown in the illustration below (NOTE: all
clearances still apply).

Approx. 16"

23-1/8"

1" Standoffs

19-5/8"

19-1/2"

Min. 1" Clearance

60-3/8"

Raised Fireplaces

The fireplace (and hearth, if desired) may be placed on a platform designed to support the fireplace
(approximately 300 Lbs.) and vent.

The fireplace may not be raised so as to place the ceiling within 75" of the base of the fireplace.

The fireplace may not be raised so as to reduce the fireplace enclosure to less than 75”.

Raised fireplace

Raised fireplace with
raised hearth.

Raised
Platform

Raised Hearth

Hearth

Raised
Platform

6-1/4"

6-1/4"