5.2 Setting

C141-E198

5-3

5.2 Setting

5.2.1

Loop ID setting

When setting the fibre channel loop ID, use SEL0 to SEL6 of interface connector CN1. IN bit
weighting, SEL6 corresponds to the MSB, SEL0 to the LSB, and 126 types of X'00' to X'7D' can be
specified as loop IDs.

5.2.2

Mode settings

(1)

Motor start mode

The method for start control of the IDD spindle motor can be set in accordance with Table 5.1.

Table 5.1

Motor start mode

Setting

Signal name

Start_2/Mated Start_1/Mated

Start

mode

Connector pin

CN1-10 CN1-09

Open

Open

The drive is not connected to the system. The drive does not start the
spindle motor.

Open

GND

The drive is connected to the system. After recognizing the
connection, the drive starts the spindle motor upon receipt of a
START/STOP UNIT command.

GND

Open

The drive is connected to the system. After recognizing the
connection, the drive starts the spindle motor after a prescribed delay
time has elapsed.

GND

GND

The drive is connected to the system. The driver starts the spindle
motor immediately after recognizing the connection.

Set the loop ID so that there are no duplicates between devices on the
same loop.