beautypg.com

FUJITSU MAS3367FC User Manual

Page 57

background image

4.1 Mounting Requirements

C141-E198

4-5

(3)

Limitation of bottom-mounting

Use all 4 mounting holes on the bottom face.


(4) Environmental

temperature

Temperature condition at installed in a cabinet is indicated with ambient temperature measured 3 cm
from the disk drive. At designing the system cabinet, consider following points.

Make a suitable air flow so that the DE surface temperature does not exceed 60°C.

Cool the PCA side especially with air circulation inside the cabinet. Confirm the cooling effect
by measuring temperature of specific ICs and the DE. These measurement results should be
within a criteria listed in Table 4.1.

Keeping the DE surface temperature at 50

°

C or below at ambient temperature 25

°

C, which is a

condition for assuring an MTBF of 1,200,000 hours, requires an air flow of 0.7 m/s.

Table 4.1

Surface temperature check point

No. Measurement

point Criteria

1

Center of DE cover

60°C

2

Read channel LSI

88°C

3 VCM/SPM

Driver

92°C

4 HDC

90°C

5 MPU

91°C


1

2

4

5

3

Figure 4.5 Surface temperature measurement points