beautypg.com

Electrical system requirements, Electrical requirements for electric dryer, Electrical requirements for gas dryer – FRIGIDAIRE 137153700B User Manual

Page 3

background image

This dryer is internally grounded to neutral unless it was manufactured for sale in Canada. Grounding through

the neutral link is prohibited for: (1) new branch circuit installations, (2) mobile homes, (3) recreational vehicles, and (4) areas
where local codes do not permit grounding through the neutral.

3

Electrical System Requirements

Electrical requirements for electric dryer

CIRCUIT - Individual 30 amp. branch circuit fused with 30 amp. time delay fuses or circuit breakers. Use separately fused

circuits for washer and dryer. DO NOT operate a washer and a dryer on the same circuit.

POWER SUPPLY - 3-wire or 4-wire, 240 volt, single phase, 60 Hz, Alternating Current.

3-WIRE POWER SUPPLY CORD KIT (not supplied)

OUTLET RECEPTACLE - NEMA 10-30R or NEMA 14-30R receptacle to be located so the power supply cord is accessible when the

dryer is in the installed position.

GROUNDING CONNECTION - See “Grounding requirements” in Electrical Installation section.

The dryer MUST employ a 3-conductor power supply cord
NEMA 10-30 type SRDT rated at 240 volt AC minimum,
30 amp, with 3 open end spade lug connectors with
upturned ends or closed loop connectors and marked
for use with clothes dryers. For 3-wire cord connection
instructions see ELECTRICAL CONNECTIONS FOR A
3-WIRE SYSTEM.

4-WIRE POWER SUPPLY CORD KIT (not supplied)

The dryer MUST employ a 4-conductor power supply cord
NEMA 14-30 type SRDT or ST (as required) rated at 240
volt AC minimum, 30 amp, with 4 open end spade lug
connectors with upturned ends or closed loop connectors
and marked for use with clothes dryers. For 4-wire cord
connection instructions see ELECTRICAL CONNECTIONS
FOR A 4-WIRE SYSTEM.

Electrical requirements for gas dryer

CIRCUIT - Individual, properly polarized and grounded 15 amp. branch

circuit fused with 15 amp. time delay fuse or circuit breaker.

POWER SUPPLY - 2-wire, with ground, 120 volt, single phase, 60 Hz,

Alternating Current.

POWER SUPPLY CORD - The dryer is equipped with a 120 volt 3-wire power

cord.

GROUNDING CONNECTION - See “Grounding requirements” in Electrical

Installation section.

Grounding type

Grounding type
wa

wall receptacl

ll receptacle

Po

Power cord with

wer cord with

3-prong

3-prong gr

grounded plug

ounded plug

Do not,

Do not, under

under

an

any cir

y circumstances,

cumstances,

cut,

cut, remo

remove

ve,

or b

or bypass th

ypass the

gr

grounding pr

ounding prong.

ong.

3-wire receptacle

(NEMA type 10-30R)

4-wire receptacle

(NEMA type 14-30R)

Because of potentially inconsistent voltage capabilities, the use of this dryer with power created by gas powered gen-

erators, solar powered generators, wind powered generators or any other generator other than the local utility company is not
recommended.

Dryers manufactured for sale in Canada have factory-

installed, 4-wire power supply cord (NEMA 14-30R).