2 caching operation – FUJITSU MPC3065AH User Manual
Page 174
C141-E056-02EN
6 - 15
6.5.2
Caching operation
The caching operation is performed only at receipt of the following commands. The device
transfers data from the data buffer to the host system if the following data exist in the data buffer.
•
All sector data to be processed by the command
•
A part of data including the starting sector to be processed by the command
When a part of data to be processed exist in the data buffer, the remaining data are read from
the disk medium and are transferred to the host system.
(1)
Commands that are object of caching operation
The following commands are object of caching operation.
•
READ SECTOR (S)
•
READ MULTIPLE
•
READ DMA
When the caching operation is disabled by the SET FEATURES command, no caching
operation is performed.
(2)
Data that are object of caching operation
The following data are object of caching operation.
1) Read-ahead data read from the disk medium in the data buffer after completion of the
command that are object of caching operation.
2) Data transferred to the host system once by requesting with the command that are object of
caching operation. But, when the sequential hit occurs continuously, the caching data
required by the host becomes invalid.
(3)
Invalidating caching data
Caching data in the data buffer is invalidated in the following case.
1) Commands other than the following commands are issued (all caching data are invalidated)
•
READ SECTOR(S)
•
READ DMA
•
READ MULTIPLE
2) Caching operation is disabled by the SET FEATURES command.
3) Command issued by the host is terminated with an error.
4) Soft reset or hard reset is executed, or power is turned off.